11
Act No. 458/2000 Coll.
The Act on business conditions and the performance of state administration in the
energy sectors and on amendments to certain laws (Energy Act)
6.2
Positioning options
When installing and using the boiler, all
requirements of CSN 06 1008 must be
complied with.
Positioning and connection of the boiler must
correspond to the project documentation. Flue
gas exhaust must comply with the applicable
regulations (Technical Regulations TPG 800
01) and the project documentation.
The space near and above the boiler must be
equal to min. 0.2 m and min. 1 m before the
boiler for the assembly and repair. The
manufacturer recommends to mount these
products into closed heating systems.
The boiler may be installed in living rooms.
It can be situated in the basic environment
according to CSN 33 2000-1 ed. 2.
K 2 L3X
K 2 L5X
L (mm)
502
587
Fig.
№
. 5
Main dimensions of the boiler
Boiler positioning with regard to fire regulations:
Safe distance from flammable materials:
−
When installing and operating the boiler it is necessary to keep the safe distance of 200 mm from flammable
materials A1, A2, B
and C (D);
−
For easily flammable materials of flammability class E (F), which burn quickly and by themselves also after the
ignition source removal (e.g. paper, cardboard, asphalt and tar boards, wood and fibreboards, plastics, flooring
materials) the safe distance is doubled, it means that the distance is 400 mm;
−
The safe distance is to be doubled also in case when the fire reaction class is not proven.
Tab.
№
. 4
Fire reaction class
Fire reaction class
Examples of building materials and products classified in reaction to fire class
(selection from CSN EN 13501-1+A1)
A1 – non-combustible
material
granite, sandstone, concrete, bricks, ceramic tiles, mortars, anti-fire plasters,…
A2 – limited combustibility
material
akumin, izumin, heraklith, lignos, boards and basalt felt, fibreglass boards,…
B – difficult to ignite
Beech, oak, hobrex boards, plywood, werzalit, Formica, sirkolit,…
C (D) – medium
inflammable
pine, larch, spruce wood, chipboard and cork boards, rubber flooring,…
E (F) – easily flammable
Asphalt board, fibreboards, cellulose materials, polyurethane, polystyrene, polyethylene, PVC,...
6.3
Delivery and accessories
The boiler VIADRUS CLAUDIUS K 2 is supplied as assembled on a pallet, packed in a carton cover and foil
protected.
Standard accessories to all boiler variants:
Operating instructions and installation manual, which includes a warranty card
The list of contractual service organizations
For the variant
CLAUDIUS
K 2 LX3, boiler sensor QAZ 36
Recommended accessories to all boiler variants:
One of spatial communication devices Siemens QAA74, QAA75, QAA55, QAA58 (wireless) QAA78 (wireless) 1
pc
Outside sensor QAC 34/101
1 pc
Recommended accessories are not included in the basic price of the boiler.