Introduction
1-1
1 Introduction
Overview
Congratulations on your choice of the EX3000 Veterinary Anesthesia System! The EX3000 is the premier
veterinary electronic dual drug delivery system in the world with safety monitoring ability. This machine
is specially designed to be compact, well balanced, and able to withstand the rigors of everyday clinical
use providing long-term safe and trouble-free performance.
This manual describes the features, safety precautions, setup, and operation of the anesthesia system. It is
recommended that you read the entire manual before attempting to operate the system.
System Safety
Operation of your EX3000 Anesthesia System involves oxygen gas pressure, electrical power, and the use
of potentially hazardous materials. In order to prevent injury to patients and/or operators and damage to
the anesthesia system, please review
Section 2 – Safety
before performing any of the procedures
contained in this manual. If you have any safety questions or comments, please contact
Vetland
or your
local distributor.
WARNING!
This veterinary anesthesia system should only be operated by veterinary
professionals qualified to administer anesthesia.
General Description
The EX3000 Veterinary Anesthesia System is a device that administers oxygen to patients. The machine
is also capable of delivering an anesthetic agent in the form of a vapor. The vaporizer converts a liquid
anesthetic into a measured amount of vapor, which is then carried to the patient by the oxygen.
Before anesthesia can be administered, the operator must connect oxygen to the anesthesia machine, fill
the vaporizer with anesthetic agent, and fill the absorber canister with absorbent. The breathing bag,
patient breathing circuit, and all accessory tubing and bags must then be connected. After the oxygen
supply is turned on and the scavenger tubing is connected to the waste gas elimination system, the
anesthesia system is ready for the daily pre-operation checkout and patient use.
The operator selects the oxygen flow rate by touching the green dot on the touch screen (see Figure 1-5)
and then touching the increase arrow (
S
) or decrease arrow (
T
) until the desired flow rate is displayed.
Next, the operator selects the anesthetic agent, such as Sevoflurane or Isoflurane, by touching the Agent
Type area of the touch screen and then using the increase or decrease arrows until the desired agent is
displayed.
Then the operator selects the anesthetic concentration percentage by touching the Vaporizer
Concentration Percentage area of the touch screen and using the increase or decrease arrows until the
desired percentage of agent to be delivered is displayed.
The wye connector of the patient breathing circuit is then attached to the mask or 15 mm endotracheal
tube connector. The gas mixture flows through the inspiration valve into the patient’s lungs. The patient
exhales through the expiration valve into the breathing bag.
In the breathing bag, the exhaled gas mixes with the constantly flowing fresh gas. The fresh and exhaled
gas mixtures are forced through the CO
2
absorber where the exhaled carbon dioxide is removed and the
ventilation cycle is repeated.
Summary of Contents for EX3000
Page 1: ...P N 410 125 EX3000 Veterinary Anesthesia System Operator s Manual ...
Page 8: ......
Page 20: ......
Page 42: ......
Page 56: ......
Page 60: ......
Page 67: ...Replacement Parts and Accessories 10 3 Figure 10 1 EX3000 Anesthesia System ...
Page 69: ...Replacement Parts and Accessories 10 5 Figure 10 3 Optional Keyfill Vaporizer Fillers ...
Page 70: ...10 6 Replacement Parts and Accessories Figure 10 4 410 105A Isoflurane Chamber Assembly ...
Page 71: ...Replacement Parts and Accessories 10 7 Figure 10 5 410 106A Sevoflurane Chamber Assembly ...
Page 72: ...10 8 Replacement Parts and Accessories Figure 10 6 410 102A Sub Chassis Assembly ...
Page 73: ...Replacement Parts and Accessories 10 9 Figure 10 7 410 108A Circuit Board Assembly ...
Page 74: ...10 10 Replacement Parts and Accessories Figure 10 8 410 100A Back Cover Assembly ...
Page 75: ...Replacement Parts and Accessories 10 11 Figure 10 9 410 101A DISS Inlet Assembly ...
Page 76: ...10 12 Replacement Parts and Accessories Figure 10 10 500 100A Pole Assembly ...
Page 77: ...Replacement Parts and Accessories 10 13 Figure 10 11 510 570A APL Pop off Valve Assembly ...
Page 78: ...10 14 Replacement Parts and Accessories Figure 10 12 510 103A Manifold Block Assembly ...
Page 79: ...Replacement Parts and Accessories 10 15 Figure 10 13 510 101A Absorber Canister Assembly ...
Page 80: ...10 16 Replacement Parts and Accessories Figure 10 14 510 129A Flush Valve Assembly ...
Page 82: ......
Page 84: ...A 2 Appendix A Figure A 2 EX3000 Pneumatic Block Diagram EX3000 Pneumatic Block Diagram ...
Page 85: ...Appendix A A 3 Figure A 3 EX3000 Electrical Block Diagram EX3000 Electrical Block Diagram ...
Page 86: ...A 4 Appendix A Figure A 4 EX3000 Electrical Connections EX3000 Electrical Connections ...
Page 87: ......