DGT / DGT60 / DGTQ / DGTP
13
3.2 DESCRIPTION OF THE STEPS
(*) tYPE TYPE OF APPLICATION (§)
One selects the type of application which will be made: scale with independent channels, a scale with dependent
channels (could be digitally equalized) or scale with independent channels simultaneously viewable on the PC.
IND.CH.
Instrument connected to 1, 2, 3 or 4 independent scales.
DEP.CH
Instrument connected to a scale with 2, 3, or 4 dependent load cells (could eventually be digitally
equalized through a specific software procedure).
TRANSM.
Independent channel mode which makes it possible to have a simultaneous transmission, through the
serial line, of the values read by each single channel (for further details see section
8.13
"SIMULTANEOUS TRANSMITTER CHANNEL VALUE", USER MAN.REF.
)
NOTE:
The configuration and the calibration of the instrument are done the same way as with the
independent channel mode.
(!) IND.CH.
(*)
With approved instrument the parameter is read-only.
(§)
The parameter is not displayed if one has selected the MASTER/SLAVE functioning mode,
FmodE
>>
FunCt
>>
MAStr
parameter.
F.ModE SCALE FUNCTIONING
•
FunCt
FUNCTIONING MODE (§)
Std
Unit of measure conversion.
ntGS
Net weight / gross weight conversion.
inout
Input / output weigh.
Once the in / out mode is selected, "tYPE" is displayed for an instant and then one is asked to select with
PRINT the print mode of the acquired data:
-
"G.t." gross/tare:
-
"1st.2nd" first weigh/second weigh:
-
"in.out" input/output:
MAStr
Multiscale Repeater.
By selecting with PRINT this functioning mode, one is asked to enter the number of SLAVES to be used: for
an instant "nuMSL" is displayed; then enter the number (between 01 and 04).
ALibi
Alibi memory.
rEPE
Single scale repeater.
UiSS
Sensitivity times ten.
hLd
Freezing of the weight on the display.
PEAK
Peak detector.
tot
o
Horizontal totalizer.
Once the horizontal totaliser functioning mode is selected, one needs to select the type of totalisation: normal
(t.norM), fast (t.FASt) or automatic (Auto).
tot
S
Vertical totalizer.
Once
the vertical totaliser functioning mode is selected, one needs to select the type of totalisation: normal
(t.norM), fast (t.FASt) or automatic (Auto).
Coun
Counting.
Once
the Counting functioning mode is selected, one needs to select the
Unit of Measure of the average piece
weight (APW):
g / kg / t / Lb,
and the sampling interval in seconds (WAit.t).
(!) ntGS
(§)
The parameter is not displayed if one has set "
trAnSM
" in the
tYPE
parameter.
Summary of Contents for DGT
Page 65: ...DGT DGT60 DGTQ DGTP 65 11 CONNECTION SCHEMES 11 1 DGT4 DGT60 DGT4 AN MOTHERBOARD I O BOOT J 1...
Page 68: ...DGT DGT60 DGTQ DGTP 68 11 2 DGT4 PB MOTHERBOARD I O BOOT J 1...
Page 71: ...DGT DGT60 DGTQ DGTP 71 11 3 DGTQ DGTQ AN BOARDS...
Page 72: ...DGT DGT60 DGTQ DGTP 72 I O BOOT J1 J2 CAL...
Page 76: ...DGT DGT60 DGTQ DGTP 76 11 4 DGTQ PB BOARDS...
Page 77: ...DGT DGT60 DGTQ DGTP 77...
Page 81: ...DGT DGT60 DGTQ DGTP 81 11 5 DGTP DGTP AN DGTP PB MOTHERBOARD...