background image

15

14

13

12

10

18

17

20

19

16

9

9

9

8

7

3

5

1

5

7

4

6

2

NTS

J.YOUNG

        T & S EQUIPMENT CO.

PERMISSION IS OBTAINED FROM

BE REVEALED ANY MANNER TO ANYONE UNLESS WRITTEN

IN WHOLE OR IN PART NOR SHALL THE CONTENTS

THIS PRINT SHALL NOT BE USED, COPIED OR REPRODUCED

T & S EQUIPMENT CO.

                T H E   P R O P E R T Y   O F

THIS PRINT IS CONFIDENTIAL AND IS

SCALE:

DATE:

APPROVED BY:

DRAWN BY:

DRAWING NUMBER:

T & S EQUIPMENT COMPANY

MATERIAL:

TOLERANCE

MACHINE

WELDMENT

FRACTIONS

FRACTIONS

DECIMALS

ANGLES

CONCENTRIC

CONCENTR

+/- 1/32

+/- 1/16

+/- .015

.006 TIR

.060 TIR

REMOVE ALL BURRS AND SHARP EDGES

x.x    +/- .025

x.xx   +/- .010

x.xxx  +/- .005

+/- 0° 30'

+/- 1° 0'

REV:

SIZE: A

073003JY-2B

DRAWING NUMBER

REV.

DATE

INITIAL

REVISIONS

REV.

DWG #:

R E V .

ECR #

073003JY-2B

AC MODULAR POWER UNIT

07/03/03

073003JY-2B

ITEM REQ

PART NO.

DESCRIPTION

1

4

71616

TSHMS, SS

2

1

01-129-001

TRANSFORMER

3

1

132560

CONTACTOR, MOTOR

4

4

27531

PHSMS, Z PLATED

5

4

32028

HWH TEK DRILL & TAP

6

3"

TB-TRACK

RAIL, DIN

7

1

01-029-006

JUCTION BOX

8

1

AB66JP

PANEL, JUNCTION BOX

9

4

C500

CONNECTOR, ROMEX, 2 SCREW

10

1

01-127-010

MANIFOLD

11

1

6801-06-06-NOW MJ-MAORB 90 DEG.

12

1

99-153-011

VALVE, CHECK 

13

1

568-015-BN70

O-RING

14

1

568-011-BN70

O-RING

15

1

99-153-015

VALVE,CARTRIDGE,NC

16

1

99-034-008

COIL, 24V AC

17

1

99-153-006

VALVE, PRESSURE RELIEF

18

1

568-334-BN70

O-RING

19

1

99-531-005

FILTER

20

1

99-153-038

FLOW CONTROL, 1.0 GPM

ITEM REQ

PART NO.

DESCRIPTION

1

4

71616

TSHMS, SS

2

1

01-129-001

TRANSFORMER

3

1

132560

CONTACTOR, MOTOR

4

4

27531

PHSMS, Z PLATED

5

4

32028

HWH TEK DRILL & TAP

6

3"

TB-TRACK

RAIL, DIN

7

1

01-029-006

JUCTION BOX

8

1

AB66JP

PANEL, JUNCTION BOX

9

4

C500

CONNECTOR, ROMEX, 2 SCREW

10

1

01-127-010

MANIFOLD

11

1

6801-06-06-NOW MJ-MAORB 90 DEG.

12

1

99-153-011

VALVE, CHECK 

13

1

568-015-BN70

O-RING

14

1

568-011-BN70

O-RING

15

1

99-153-015

VALVE,CARTRIDGE,NC

16

1

99-034-008

COIL, 24V AC

17

1

99-153-006

VALVE, PRESSURE RELIEF

18

1

568-334-BN70

O-RING

19

1

99-531-005

FILTER

20

1

99-153-038

FLOW CONTROL, 1.0 GPM

Summary of Contents for JMD-1000

Page 1: ...o not perform any modifications to the tote dumper without the manufacturer s approval Failure to receive authorization for changes to the equipment could void the warranty Maintenance and repairs are...

Page 2: ...ng or flying material when dumping loads Do not use the dumper if any damage or unusual noise is observed Do not perform any modifications to the dumper without the manufacturer s approval Failure to...

Page 3: ...motor when the carriage reaches its maximum rotation angle Pressing the DOWN pushbutton will energize the lowering valve to allow the carriage to descend Again releasing the control will stop the carr...

Page 4: ...r functioning of the upper travel limit switch B In addition to the above inspect monthly for 1 The oil level Oil should be 1 to 1 below the reservoir s fill hole with the chute fully tilted 2 Worn or...

Page 5: ...MOTOR TRANSFORMER CONNECTION DIAGRAMS CAUTION If the motor voltage is changed the wire on the control transformer s primary wire has to be changed to match the new motor voltage also...

Page 6: ...ELECTRICAL DIAGRAMS MODULAR POWER UNITS...

Page 7: ...nical devices and their associated electrical and hydraulic circuits should attempt troubleshooting and repair of this equipment CAUTION Do not use brake fluid or jack oils in the hydraulic system If...

Page 8: ...R 2 33008 USS FLAT WASHER Z PLATED 12 1 01 627 010 MANIFOLD ASSM SEE PAGE 2 13 1 01 143 906 PUMP 14 1 HS52 CLAMP WORM GEAR 15 1 091802JY FIBERGLASS COVER 16 3 ZB2BZ009 BASE CONTACT BLOCK 17 3 ZB2BE101...

Page 9: ...28 HWH TEK DRILL TAP 6 3 TB TRACK RAIL DIN 7 1 01 029 006 JUCTION BOX 8 1 AB66JP PANEL JUNCTION BOX 9 4 C500 CONNECTOR ROMEX 2 SCREW 10 1 01 127 010 MANIFOLD 11 1 6801 06 06 NOW MJ MAORB 90 DEG 12 1 9...

Page 10: ...lowly when the motor stops Solenoid stuck open slightly by speck of contamination or a bent valve stem Check valve stuck open by speck of contamination Unit raises but lowers quickly when the motor st...

Page 11: ...consequential and incidental damages is expressly disclaimed The manufacturer s liability in any event is limited to and shall not exceed the purchase price paid Misuse will and modification might voi...