Installation Broken glass indicator
3. Apply the adhesive to the side of the broken glass indicator
that is marked with a black bar.
Important:
Make sure to keep the adhesive areas clean and
oil-free.
4. Place broken glass indicator carefully onto to the window
pane and make sure to clear the window frame by minimum
2 inches. Attach the broken glass indicator with adhesive
tape and ensure that it is located perpendicular, with the
cable going off to the bottom (please refer to the picture on
page 71).
5. Plug the jack of the broken glass indicator into the
left-hand
socket
of the roller shutter control.
6. Push the selector switch all the way to the left until it clicks to
set the automatic control to
(A).
7. Functional test:
Take a coin and tap the broken glass indicator with it in order
to simulate breaking glass. The roller shutter will now move
down and the display will indicate the broken glass symbol.
Press the
up
button to stop the roller shutter and delete the
broken glass signal.
Remove the adhesive tape after the adhesive has hardened.
Please check the instructions on the adhesive packaging for the
processing and hardening times.
- 72 -
G
Broken glass indicator Installation
The additional function “broken glass indicator” requires an extra
broken glass indicator for each
Vestamatic
Rollmat Plus G/S V3.1
roller shutter control (for larger or separated window panes).
The installation of the sun sensor is described below.
1. Push the selector switch all the way to the right until it clicks
to set the
manual control
to
(H).
2. Mix binder and hardener of the two-component adhesive
thoroughly in a 1 : 1 ratio.
- 71 -
G