Notes for professional electricians Installation
Installation and basic settings:
1. Switch off the power supply.
2. Remove the band winder from the band winder case.
3. Set the DIP switches to the desired function (see pages 57
to 61).
4. Connect the
Vestamatic
Rollmat Plus G/S V3.1
according to
the wiring diagram (see page 70).
Attention: Currently valid VDE standards must be ob-
served when connecting the device, in particu-
lar DIN VDE 0100/0700 as well as the currently
valid regulations of your local power company
and accident prevention regulations.
5. Install the
Vestamatic
Rollmat Plus G/S V3.1
in the band
winder case.
6. Set the selector switch to manual mode
(H),
i.e. push it to the
right all the way to the stop.
7. Switch on the power supply and press the
reset
button.
8. Check, if the direction of the motor rotation corresponds with
the direction buttons. If not, exchange terminal 6 with ter-
minal 7.
- 67 -
G
Installation Notes for professional electricians
Important:
Parallel control of several roller shutter drive motors
can only be implemented by means of isolating
relays or group control devices.
In case of power failure, the display contrast will fade
which does
not
indicate that the battery is empty.
For extra large band winder cases, we
recommend to use our intermediate plate, article-no. 01201500.
For the broken glass indication and the sun sensor function, the
following accessories are available:
Broken glass indicator, cable length 1 m, article-no. 01200120
Broken glass indicator, cable length 2 m, article-no. 01200220
Broken glass indicator, cable length 3 m, article-no. 01200320
Broken glass indicator, cable length 5 m, article-no. 01200520
Broken glass indicator, cable length 8 m, article-no. 01200820
Broken glass indicator, cable length 10 m, article-no. 01201020
Broken glass indicator and distributor box, article-no. 01201120
Sun sensor, cable length
1 m, article-no. 01130120
Sun sensor, cable length
2 m, article-no. 01130220
Sun sensor, cable length
3 m, article-no. 01130320
Sun sensor, cable length
5 m, article-no. 01130520
Sun sensor, cable length
8 m, article-no. 01130820
Sun sensor, cable length
10 m, article-no. 01131020
For control via two drives, we recommend our isolating relays:
Isolating relays TR N2S,
article-no. 01054220
Isolating relays TR N2A,
article-no. 01054120.