Installation Sun sensor
After completing the installation, activate the quick run function
in order to check the additional function “sun protection” by
pressing the
time
and
day
button simultaneously for 3 seconds
(this will make the time run 60 times faster). That way you can
check the entire functional sequence within a short amount of
time.
Example of a test run:
1. Check whether you are within the range of the programmed
up and down times.
2. Press the
time
and
day
button simultaneously for 3 seconds.
3. Expose the sun sensor to light until the sun symbol flashes.
After approx. 1 second the shutter moves to the shade posi-
tion.
Remove the light source.
The sun symbol in the display will flash again.
After 16 seconds, the roller shutter will move up again.
4. Press the
time
and
day
button shortly after the test run is
completed.
5. Set the current time as described on page 48.
- 74 -
G
Sun sensor Installation
The additional function “sun protection” requires an extra sun
sensor for each
Vestamatic
Rollmat Plus G/S V3.1
roller shutter
control. The installation of the sun sensor is described below.
1. Plug the sun sensor jack into the
right-hand socket
of the
roller shutter control.
2. Attach the sun sensor on the desired area of the window.
3. Push the selector switch all the way to the left until it clicks to
set the automatic control to
(A).
- 73 -
G