User Manual Vesala PK2 Receiver X2.0 ENG
4 (22)
1
Safety notes
To avoid possible harm, read and follow these instructions.
DANGER
: Risk of electric shock, fire, or property damage
Drilling a structure may damage a dangerously live electric cable or a pressurised pipe. Before
drilling a structure, make sure the structure doesn’t contain dangerously live cables or
pressurised pipes. If their existence cannot be excluded, the whole installation containing the
structure should be de-energized and de-pressurised before drilling begins. In some cases, a
decrease in locating accuracy may move the intended drill point.
ATTENTION
: Risk of locating error due to electromagnetic conditions
Large metallic objects, radio transmitters or industrial equipment may degrade locating
accuracy or may prevent locating completely. Before attempting to locate a drill hole, take care
that there are no large metallic objects at or near the intended drill hole. Large metallic objects
include radiators, sheet metal, foil, and wire mesh among other things. Shut down or move any
radio transmitters that actively transmit on the same frequency at least 10 m away from the
intended drill hole. This includes other drill point locators.
ATTENTION
: Risk of locating error due to device misorientation
Locating drill points with misoriented devices may degrade locator performance. Instructions
for properly orienting the devices are provided in section 4: Operating receivers.