Adjustments
Diagnostics Section
©Vertical Express
3-10
Printed in USA April 2020
This manual shows only the parameters that have an operational relevance to the ICON32. The UIT may have
additional parameters available, which should not effect the controller operation.
L18
floors
1–nfloors
Zone 5 Floor - See L14.
L19
floors
1–nfloors
Zone 6 Floor - See L14.
L20
zones
0–6
Number of Zones - The maximum number of zones or parking floors in the group.
Notes
:
• If this number is set larger than the number of cars, the parking floors (or zone floors)
will be rotated on each assignment.
• This parameter is usually set to a value less than total number of cars.
See also: L14.
L25
2 sec.
0–60
Park Free Time - This adjustment sets the amount of time the car must be free in order to
zone.
See also: L14.
M10
—
1-5
Motor Starter Type.
Values:
1 = Across Line - One Contactor
2 = Across Line -Two Contactor
3 = Delta One Contactor
4 = Wye-Delta -Two Contactor
5 = Electronic
M11
0.1 sec.
0-20
Motor Starter Time - Wye-Delta interval timer value.
M12
—
1-7
Valve Type - This adjustment sets the active solenoids during a high speed UP or DOWN
run.
Values:
1 = Up fast only, Down fast, and Down slow (tkE I-2/I-3 Valve)
2 = Up fast only, and Down fast only
3 = Up fast and Up slow, Down fast only
4 = Up fast and Up slow, Down fast and Down slow (Maxton Valve)
5 = Dump valve, Down fast, and Down slow
6 = Dump valve, and Down fast only
7 = Electronic Valve
M13
0.1 sec.
20-6000
Restart Delay - This adjustment sets the amount of delay time from the end of one run until
the beginning of a new run (relevel runs do not count).
M14
0.1 sec.
1-30
Motor Stop Time (previous label, TMS Timer) - This adjustment sets the time delay
between the Up Valve deactivation and the motor deactivation.
M79
min.
0-60
Landing Timer - If the car run time exceeds this value, the car is shutdown and requires a
manual reset or power cycle.
O10
calls
0-nf
Anti-nuisance Car Calls - This adjustment sets the number of car calls answered (without
passenger detection) before activating the anti-nuisance operation.
O11
inches
0–168
Hoistway Access Bottom Zone - When the car runs on hoistway access, this zone is the
distance (in inches) above the bottom hoistway access floor.
Note:
Modifying this parameter requires SP & NP Configuration.
See also: O21, O22, Z38, and Z39.
O12
floor
0–nf
Car Cycle Floor 1 - This adjustment sets the car cycle for floor 1, and the car will cycle
between floors 1 and 2. To deactivate this feature, set either O12 or O13 to 0 (zero).
O13
floor
0–nf
Car Cycle Floor 2 - This adjustment sets the car cycle for floor 2, and the car will cycle
between floors 1 and 2. To deactivate this feature, set either O12 or O13 to 0 (zero).
O14
floor
0–nf
Hall Independent Return Floor - This adjustment sets the return landing of the car (when
Hall Independent Service is activated).
O15
F/R
0–1
Hall Independent Return Door - This adjustment assigns which door will open at the return
landing (when the landing has with selective doors).
Values:
0 = Front
1 = Rear
Adj
(cont.)
Unit
Range
Definition
(cont.)
Summary of Contents for ICON 32
Page 1: ...Controller...
Page 3: ...INSTALLATION SECTION...
Page 4: ...INSTALLATION SECTION...
Page 39: ...ADJUSTMENT SECTION...
Page 40: ...ADJUSTMENT SECTION...
Page 83: ...DIAGNOSTICS SECTION...
Page 84: ...DIAGNOSTICS SECTION...
Page 131: ...TROUBLESHOOTING SECTION...
Page 132: ...TROUBLESHOOTING SECTION...
Page 165: ...SERVICE INFORMATION SECTION...
Page 166: ...SERVICE INFORMATION SECTION...
Page 205: ...REFERENCE SECTION SERVICE REFERENCE SECTION...
Page 206: ...REFERENCE SECTION...