7
Oxford Direct Vent / Natural Vent Gas Heater
30005123
corner Installation:
Minimum clearance and Flue centerline
Direct Vent and Natural Vent
ST129c
Dutchwest
corner specs
5/15/03 djt
A
A
B
B
ST129c
Stove Clearance
A: 4” (102 mm)
Pipe Centerline
B: 14
Z\x
” (370 mm)
Fig. 4
Corner installation, minimum corner clearances and flue
centerline.
Wall and ceiling clearances
A
C
D
ST1122
Min. clearance
B
A: Rear Wall
4” (102 mm)
B: Min. Clearance
45
Z\x
” (1156 mm)*
C: Min. Alcove Height
73
Z\x
” (1867 mm)*
D: Max. Alcove Depth
48” (1220 mm)
Sidewall Clearance
4” (102 mm)
* needed for installing DuraVent Minimum Vent Kit #2792 or Vermont Cast-
ings Group Minimum Vent Kit #7TFSDVSK.
ST1122
Fig. 6
Dimensions and clearances to ceiling or alcove.
Wall centerline from Floor
ST1121
wall thimble
A
A
Effective Minimum
Wall Thimble
57
Z\x
” (1461 mm) (Vermont Castings Group
Pipe)
Centerline
53
Z\x
” (1359 mm) (Simpson DuraVent Pipe)
ST1121
Fig. 5
Minimum wall thimble centerline.
Hearth Requirements
The heater must be installed on rigid flooring. When the
heater is installed directly on any combustible surface
other than wood flooring, a metal or wood panel extend-
ing the full width and depth of the unit must be used as the
hearth. There are no other hearth requirements.
parallel Installation:
Minimum clearance and Flue centerline,
Direct Vent and Natural Vent
ST128b
Stardance
flue centerline
9/28/00 djt
C
L
C
L
B
D
C
A
Stove Clearances
A: 4” (102 mm)
B: 4” (102 mm)
Pipe Centerlines
C: 15
Z\x
” (395 mm)
D: 9” (229 mm)
Fig. 3
Parallel installation, minimum back and side clearances
and flue centerlines.
ST128c