6
Oxford Direct Vent / Natural Vent Gas Heater
30005123
Installation Requirements
The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do
not derate this appliance for altitude. Maintain the mani-
fold pressure at 3.5” w.c. for Natural Gas, and 10” w.c. for
Propane).
In Canada, installation must be in accordance with the cur-
rent CSA B-149.1 Installation Codes and/or local codes.
The installation should be done by a qualified service
person who is familiar with the building codes and
installation techniques appropriate for your area to
accomplish a safe and effective installation.
Your dealer or your local gas supplier will be able to
refer a qualified service person.
WARNING: Due to high temperatures, the HEATER
should be located out of traffic and away
from furniture and draperies.
The surface of the Heater Is hot when it is
in use. Young children should be watched carefully
when they are in the same room when the Heater is in
use, and they should be taught to avoid the hot sur-
face. Keep any objects that can burn well away from
the Heater, and observe the recommended clearanc-
es that follow.
A
B
E
C
D
ST207b
Dutchwest
Stove locations
5/15/03 djt
Direct Vent System Only
A. Flat on corner wall D. Cross Corner
B. Room Divider
E. Flat on wall
C. Island
ST207b
Fig. 2
Possible stove locations.
clearance Requirements
Minimum clearances to
combustible Materials
Measure side clearances as shown in Figures 5 and 6
from the outer edge of the cast iron stove top. Measure
rear clearances from the outermost surface of the steel
rear skirt.
The heater is approved for installation into an alcove con-
structed of combustible materials to the dimensions and
clearances shown on the next page.
The same clearances apply in a standard parallel instal-
lation.
Warning:
• Always maintain required clearances (air
spaces) to nearby combustibles to prevent
fire hazard. Do not fill air spaces with insula-
tion. All venting components must maintain a 1”
(25 mm) clearance to combustible materials. Main-
tain a 6” (150 mm) clearance when using a single
wall pipe.
• The gas appliance and vent system must be vented
directly to the outside of the building and never be
attached to a chimney serving a separate solid fuel
or gas-burning appliance. Each direct vent appli-
ance must use its own separate vent system. Com-
mon vents are prohibited.
• Refer to the manufacturer’s instructions included
with the venting system for complete installation
procedures.
WARNING
!
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Locating the Stove
In choosing a location for the stove, consider:
• The location of outside walls;
• Where additional heat is needed:
• Where family members gather most often;
• The vent system requirements.
NOTE:
We do not recommend the use of wallpaper next
to this stove. Over time, radiant heat may cause the wall-
paper to shrink, or may adversely affect the binders in the
wallpaper adhesive.