14
Defiant Woodburning Stove
30003841
A Damper Directs Air Flow
Within the Stove
The
damper handle
on the left side of the stove oper-
ates the damper to direct air flow within the stove.
The damper is
open
when the handle points to the
rear
, enabling smoke to pass directly into the chimney.
The damper must be open when starting or reviving a
fire, and whenever the griddle or doors are opened.
� � � � � � �
D E F I A N T
� � � � � � �
D E F I A N T
� � � � � � �
D E F I A N T
ST541
thermostat
settings
11/00
Low Heat
Range
Air Control Positions
Medium Heat
Range
High Heat
Range
ST542
Fig. 21
The handle also may be positioned anywhere be-
tween the two extremes for different heat levels.
� ����
� �
D E F I A N T
� ����
� �
D E F I A N T
ST543
Damper
positions
11/00
Damper Positions
Open
(Updraft Mode)
Closed
(Catalytic Mode)
ST543
Fig. 22
The Defiant’s damper operating positions.
Two Ways to Add Fuel
The Defiant’s griddle lifts for convenient top-loading of
logs, and is the easiest way to add fuel. (Fig. 23)
Defiant
ST521
Intrepid
loading
11/00
ST521
Fig. 23
Top loading is the best way to add fuel during regular
use. Front loading is useful for kindling a fire.
A Single Air Control Regulates
Heat Output and Burn Time
The
primary air control lever
, on the right side of the
stove, controls the amount of incoming air for starting,
maintaining, and reviving a fire.
More air entering the stove makes the fire burn hotter
and faster, while less air prolongs the burn at a lower
heat output level. (Fig. 21)
For the greatest air supply and maximum heat output
(but the shortest burn time), move the lever toward the
front of the stove. For a fire that will last longer with
less heat, move the lever toward the rear of the stove.
The Defiant’s air control system includes an automatic
thermostat to ensure an even heat output at whatever
manual setting you select. The thermostat senses the
heating and cooling of the stove surface and adjusts
the air valve accordingly.
The damper is
closed
when the handle points
forward.
Smoke travels through the catalytic combustion system
where it can be further burned, before passing up the
chimney. (Fig. 22)
The damper is either fully open or fully closed.
There are no intermediate positions. When closing
the damper, be sure to pull firmly enough to snap
the handle into the locked position.
In addition, however, the front doors open for adding an
occasional log to a fire.
The Defiant is not approved
in Europe for operation with the front doors open.
To open the front doors, insert the handle into the door
latch stub and turn it to the left and up. (Fig. 24)
ST544
door open
11/00
Clockwise to
Open
Counter-
clockwise
to Close
ST544
Fig. 24
To open the front doors, turn the handle clockwise.