background image

25

Defiant Woodburning Stove

30003841

T

he Catalytic Element

This wood heater contains a catalytic combustor, which 
needs periodic inspection and replacement for proper 
operation. In the United States it is against the law to 
operate this wood heater in a manner inconsistent with 
the operating instructions in this manual, or if the cata-
lytic element is deactivated or removed. 
Under normal operating conditions, the catalytic com-
bustor should remain active for two to six years (de-
pending on the amount of wood burned). However, it 
is important to monitor the combustor periodically to 
ensure that it is functioning properly, as well as to de-
termine when it needs to be replaced. A non-functioning 
combustor will result in a loss of heating efficiency, and 
an increase in creosote and emissions.

Inspection and Cleaning

Inspect the combustor “in place” for fly ash accumula-
tion and physical damage three times per year. Clean 
the combustor as needed. Do not remove the com-
bustor unless a more detailed inspection is warranted 
because of diminished performance as outlined in the 
next section. 
The refractory package that houses the catalytic com-
bustor should be inspected annually for a buildup of fly 
ash and cleaned if necessary. This may be done when 
you examine the combustor.

When to Suspect a Combustor Problem

The best way to evaluate the performance of your 
Defiant’s combustor is to observe the amount of smoke 
leaving the chimney — both when the combustor has 
“lighted-off” and when it has not. Follow these steps: 

• 

With a fire going and the combustor properly activat-
ed, with the damper closed to route smoke through 
it as described in the Operation Section, go outside 
and observe the smoke leaving the chimney.

• 

Then, open the stove damper and once again check 
the smoke leaving the chimney. 

 

You should see significantly more smoke when the 
stove damper is open and exhaust does not pass 
through the combustor. However, be careful not to 
confuse smoke with steam from wet wood. Steam dis-
sipates in the air quickly; smoke does not. 
If this test indicates a problem, consider other possible 
factors as well, such as the weather or a change in the 
quality of your fuel. In warm weather, draft is weaker 
than it is in colder winter weather, and fires can burn 
sluggishly. Small, hot fires are a good solution under 
these conditions.

Burning “green” (insufficiently seasoned) wood will 
result in poorer performance than burning properly 
seasoned fuel. You may have to run your stove hotter 
(more air) to achieve acceptable performance using 
green or wet wood. 
Also, consider any changes in your operating routine.
Once you have ruled out any other possible causes for 
a decline in performance, inspect and clean the com-
bustor if necessary. Be sure to protect any surface you 
use for setting the stove parts aside. 

Inspecting the Combustor

1.  Lift the throat off its support brackets, and then 

remove it from the stove and place it on a protected 
surface. (Fig. 35)

2.  Use a flashlight, and a mirror if necessary, to exam-

ine the combustor. If no fly ash or damage is visible, 
the inspection is complete and you may replace the 
baffle. If closer examination or cleaning is needed, 
go to the next section.  

ST555

Inspect 

Catalytic element

11/00

Baffle Support 

Brackets

Catalytic 

Element

ST555

Fig. 35

  Lift the baffle off its supports to inspect the catlyst.

Removing and Cleaning the Combustor

1.  Remove the firebricks. Lift off the steel clip and  

remove the bricks individually. (Fig. 36)

2.  Tap the left and right wedges upward, and remove 

the lower fireback by pulling it forward. You can 
either let it lie face down on the firebox floor, or re-
move it from the stove, through the front door open-
ing. (Fig. 37)

Summary of Contents for Defiant 1945CE

Page 1: ...INSTALLED OPERATED AND MAINTAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR...

Page 2: ...of warmth beauty and comfort in your home At CFM Corporation we share that joy and appreciation for the hearth We assure you that your cast iron Vermont Castings stove has been made with the utmost c...

Page 3: ...rior using new technologies for ef cient combustion Americans purchased over a quarter million De ants as they rediscovered the common sense of heating with wood a home grown fuel with none of the pol...

Page 4: ...N T 826 mm 32 724 mm 28 788 mm 31 96 mm 3 546 mm 21 489 mm 19 464 mm 18 546 mm 21 3841 Defiant EU dimensions 7 06 768 mm 30 D E F I A N T 591 mm 23 489 mm 19 654 mm 25 C L 737 mm 29 Flue exit position...

Page 5: ...ng a chimney or house re Follow all instruc tions exactly and do not allow makeshift compro mises to endanger property and personal safety All local regulations including those referring to national a...

Page 6: ...t be operated with the front doors open Whatever the ue collar size an De ant may be vented into larger chimneys as well However chimneys with liners larger than 203 x 305 mm 8 x 12 may experience rap...

Page 7: ...Flue Gas Direction Toward Stove ST242 Fig 4 Chimney connector ue collar with three 10 x 1 2 sheet metal screws Lift off the griddle and shield the stove s surface between the griddle opening and the...

Page 8: ...above the replace opening Seal This Off ST243 thinble connection 12 13 99 djt Thimble Sleeve Chimney Connector Flue Keep sleeve end ush with ue tile ST243 Fig 6 The thimble made of either ceramic or...

Page 9: ...NOT CONNECT THE DEFIANT TO ANY AIR DIS TRIBUTION DUCT OR SYSTEM ST245 fireplace flex connector 12 99 Flexible Connector Mantel Shield Fireplace Adapter Kit Positive Connection ST245 Fig 8 Through the...

Page 10: ...De ant Costructional Hearth Dimensions as below At least 300 mm At least 150 mm or to a suitable heat resistant wall At least 150 mm Hearth Surface Free of Com bustible Material Perimeter should be c...

Page 11: ...A Minimum distance from stove to movable combus tible materials e g furniture drying clothes etc 1220 mm 48 ST486a Defiant EU Clearance Diagrams 10 06 A B ST486a Fig 11 Minimum clearances D at least 3...

Page 12: ...g the stove especially across rough surfaces can cause the legs to loosen or even break Storing the Handle Use the removable handle to open or close the doors After using it remove the handle so it wi...

Page 13: ...ew to attach the damper handle to the damper stub on the left side Attach the Primary Air Thermostat Handle The primary air thermostat handle is the smaller of the two black handles Secure the handle...

Page 14: ...e stove controls the amount of incoming air for starting maintaining and reviving a re More air entering the stove makes the re burn hotter and faster while less air prolongs the burn at a lower heat...

Page 15: ...nd air dried outside under cover for at least one year If hardwood is not available you can burn softwoods that include tamarack yellow pine white pine East ern red cedar r and redwood These should al...

Page 16: ...to get quite hot within a few minutes after a re is started the combus tor may stop working or the re may go out if the re dies down immediately as a result of the damper being closed Once the combus...

Page 17: ...e it is in use 3 Light the newspaper and close the door Gradually build up the re by adding a few 76 127 mm 3 5 di ameter splits If this is one of the rst few break in res let the re burn brightly and...

Page 18: ...sn t working Note that the catalyst is most likely to glow at its higher temperatures which it reaches when the rebox is in its lower range the catalyst is an after burner and the more waste fuel ther...

Page 19: ...erial Return the ash pan to its original position in the stove and close and latch the ash door Fig 31 Do not operate the stove with the ash door open This will result in over ring and could cause dam...

Page 20: ...the home An indoor chimney won t lose its heat to the outdoors so it takes less heat from the stove to heat it up and keep it warm Chimney Height The common wisdom tells us that a taller ue draws bet...

Page 21: ...sture meters available for rewood you can also judge your wood by its appearance and weight If you get it green lift a piece and get a sense of its weight it can lose a third or more of its weight as...

Page 22: ...crack a nearby window or door to enable the chimney to pull well that s a sign that you should install an outside air intake to bring combustion air directly to the stove An outside air adapter will a...

Page 23: ...ss with water or a cleaner made espe cially for this purpose Do not use abrasive cleaners Use cleaning agents sparingly and be sure to keep them off the outer surfaces of the stove Rinse the glass tho...

Page 24: ...he pressure screw from turning as you tighten the nut Re test the damper Tighten the Damper Handle as Needed A handle on the left side of the stove controls the damper The handle attaches to the dampe...

Page 25: ...he stove damper and once again check the smoke leaving the chimney You should see signi cantly more smoke when the stove damper is open and exhaust does not pass through the combustor However be caref...

Page 26: ...ing its effectiveness ST558 Inspect Catalytic element 4 11 00 Catalytic Ele ment Catalytic Access Panel ST558 Fig 38 Remove and inspect the catalytic element 5 Inspect the element for damage or degrad...

Page 27: ...need periodic replacement The sizes of replaceable gasket are listed below along with their applications Gasket Diameter And the Parts it Seals 5 16 The griddle to the stove top wire reinforced gaske...

Page 28: ...everyone out of the house Call the Fire Department Inspect the system every two weeks during the heat ing season as part of a regular maintenance schedule To inspect the chimney let the stove cool com...

Page 29: ...alyst is still there it is covered or masked by the contaminant and cannot function To avoid this situation it is important not to burn any thing in your De ant that is a source of these contami nants...

Page 30: ...roper clearance between chimney and nearby combustibles less than 51 mm 2 check local codes K Loose or leaky cleanout door For a replace F Improper clearance between smoke chamber and framing material...

Page 31: ...9 85 86 87 70 78 71 88 59 90 52 91 91 CFM Corporation reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice De ant...

Page 32: ...rt 1300642 58 Ashpan Bracket 30001908 59 Primary Air Valve Assy 5000024 60 Primary Air Frame3 1307411 61 Primary Air Rod3 1600058 62 Primary Air Valve3 1307412 63 Thermostat Handle Wood 1600660 64 Air...

Page 33: ...0001612 1320621 30001616 Suede Brown 30002578 30002574 30002573 30002575 30002583 30002580 Vermont Classic Green 30002997 30002993 30002992 30002994 30002991 30002998 Shell Enamel Parts De ant Enamel...

Page 34: ...34 Defiant Woodburning Stove 30003841...

Page 35: ...te 3 Date of failure of catalyst 4 Any relevant information or circumstances regarding determina tion of failure 5 In addition the owner must return the failed catalyst Exclusions Limitations 1 This w...

Page 36: ...CFM Corporation 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...