37
Chateau™ Direct Vent Gas Fireplace
20011957
American Flame Gas Control System Error Codes
Ignition Safety:
Protection for Ignition System
Error Code:
One beep every one second
Description of Fault:
Warn users if the pilot is not successfully ignited in 60 seconds.
How to Clear:
Press OFF then ON buttons to re-attempt ignition.
What to Check:
•
Ensure gas supply is turned on.
•
Ensure orange/white leads from module are plugged into the “PILOT” connection on the valve body.
•
Verify the lead from igniter on pilot assembly is connected to the “I” terminal on the module.
•
Verify lead from flame sensor on pilot assembly is connected to the “S” terminal on the module.
•
Verify that the black ground lead form the module is connected to a proper ground on the fireplace.
•
Ensure there is no blockage in the pilot line.
Sensor Safety:
Protection for Flame Sensor
Error Code:
4 beeps every one second
Description of Fault:
Warn users the pilot flame sensor detects a pilot flame already present when ignition sequence
is initiated. This fault will also occur if pilot flame sensor is shorted to ground.
How to Clear:
Press OFF then ON buttons to re-attempt normal ignition.
What to Check:
•
Check if pilot flame is actually present when valve is turned OFF (valve replacement necessary if yes).
•
Replace pilot assembly.
•
Replace module.
Thermal Safety:
Overheat Protection
Error Code:
4 beeps every two seconds.
Description of Fault:
Warn users that the module’s internal temperature has exceeded 170° F (77° C).
How to Clear:
Module’s internal temperature must cool to below 160° F (71° C) and then press ON button.
What to Check:
•
Is module located in unapproved location, too close to burner?
•
Move to cooler location.
Communication Safety:
(
NOTE:
This feature is only available when transmitter includes an LCD screen).
Error Code:
One beep every four seconds.
Description of Fault:
Warn users that the transmitter and receiver are not communicating properly.
What to Check:
•
Verify batteries in both transmitter and receiver are new.
•
Ensure transmitter is located within 20 feet (6 m) of receiver.
•
Ensure transmitter is not placed in metal enclosure or laying directly on top of a metal surface as this can interfere
with transmission.