9
Chateau™ Direct Vent Gas Fireplace
20011957
Pilot
Main
AF-4000
DC Motor
Red
Black
White or Green
Green or White
Orange or White
Black
Brown
Red
Orange
Main
Module
Black
Gnd
Brown
Brown
Black
Red
(SWI)
(SWI)
Extension Harness
FP1795
Chateau wiring diagram
3/07
White or Orange
S
I
AC Adaptor
Power
Module
To Pilot Ignitor
To Pilot
Flame Sensor
Remote Battery
Back-Up Pack
Red
Black
Learn
Button
Remote/Off
Switch
Continuous
Pilot ON/OFF
Switch
(Optional
ON/OFF Switch)
Pulse/Continuous
Button
FP1795
Fig. 9
DVT38S2 wiring diagram.
19. Mount electrical wall box containing back-up bat-
teries at a convenient location from 3’ (914 mm) to
15’ (4.6 m) of the fireplace. Cover wall box using a
blank wall plate.
20. The fireplace remote system is ready for use.
21. Reassemble access panel, burner assembly, gas
supply connector, brick panels, logs, embers,
andirons and lava rock in reverse order of removal.
(Refer to Log, Lava Rock and Ember Placement
section.
22. Turn on gas supply and check that all connections
are tight and leak free.
NOTE:
If you need to test the inlet pressure and/or
manifold pressure, there are two (2) test ports available
along the front edge between the firebox side and outer
casing. The upper test port is inlet pressure. The lower
test port is manifold pressure. (Refer to Figure 8)
CAUTION: Turn off the gas supply before
removing test port plug.
23. Using a 7/16” nut driver, remove the threaded plug
from the test port.
24. Thread the supplied extension adaptor into the
open test port.
25. Attach a 1/4” diameter pressure gauge flexible hose
fully onto the barb of the adaptor.
26. Turn on gas supply and operate valve with remote
control as needed to indicate gas pressure.
CAUTION: Turn off the fireplace and gas
supply before removing test port adaptor
and replacing plug.
27. After test, remove extension adaptor and replace
plug securely.
28. Turn on gas supply and check that plugs are tight
and leak free.
Special Feature for Cold Climates
This gas control system has the option of a continu-
ous pilot feature. This allows the user to change from
a spark to pilot system to a standing pilot system for
direct vent appliances during cold climate conditions to
keep the firebox warm.
When the continuous pilot mode is activated and the
fireplace is turned ON, the pilot will spark and light.
When the fireplace is turned OFF, the pilot will stay ON
when the main burner shuts OFF.
The continuous pilot mode can be activated or de-acti-
vated by the hand held remote control transmitter.