RFS INSTALLATION INSTRUCTIONS
VERIZON HYBRIFLEX CABLE| Revision 1 | APRIL 2019
Visit
for the most current product specifications
Page 8 of 33
HYBRIFLEX® 6x12 configuration/color coded scheme
Quick reference
Cable type
HB078-U2S4-xx-LI
HB114-U6S12-xx-LI
Cable Type
HYBRIFLEX® Low Inductance
Size
7/8”
1-1/4”
Conductor gauge
6 AWG
6 AWG
Number of DC Pairs
2 pairs
6
Number of fiber pairs
6 pairs
12 pairs
Hybrid armor type
Corrugated Aluminum
Corrugated aluminum
Hybrid fiber mode
Single
Single
Hybrid termination
Top: DLC | Bottom: DLC
Top: DLC | Bottom: DLC
Hybrid weight (kg/m (lb/ft))
1.04 | 0.7
2.52 |1.7
Max over jacket diameter
28.2mm | 1.11”
39mm | 1.54”
Breakout fiber length mm(in)
1371.6 +/-50.8 | 54 +/-2‘’
939.8 +/-50.8 | 37 +/-2”
Breakout power length, mm(in)
124mm | 5”
812mm | 8”
Hybrid minimum bend radius Sg
127mm | 5”
152mm | 6”
Alarm Wire
10 (5 standard pairs) @ 0.8
mm2 (18 AWG)
18 (9 standard pairs), 0.8 mm2 (18), 6 AWG
Ref. only in no particular order