Verint Video Intelligence Solutions
113
Nextiva S4200 Series User Guide
Both surge protection modules offer standard RJ-45 jacks for inbound and outbound
termination. To install any of these modules, you need to cut and splice the outdoor
Ethernet cable this way:
The maximum length of the Ethernet connection with these surge protection modules
installed is 75 meters.
Obviously, you must properly connect the S4200 device to the ground. Use a good
grounding conductor and connect it to the ground lug on the S4200; make the connection
to the ground system as short as possible. The grounding conductor should be a round
cable with a minimum AWG 10 (2.6 mm) and maximum AWG 1 diameter, or the grounding
wire that was provided with your protection module. On the S4200, the nearest grounding
point is the pole itself.
Surge protector
Electrical box
Less than 1 meter