Verint Video Intelligence Solutions
101
Nextiva S4200 Series User Guide
System status—For the general device status:
The following power-up conditions on the three status LEDs are abnormal:
LED not lit—Check the power supply and cabling. If power is available and the LED
stays off, call Verint Video Intelligence Solutions technical support for assistance.
Steady red or green LED for more than 30 seconds—There is an internal error that
prevents the device from starting normally. Power down the device, wait 30 seconds,
then power it up. If the condition persists, call Verint Video Intelligence Solutions
technical support.
Using the Command Line Interface
You may need to access the command line interface (CLI) of an edge device to perform
troubleshooting tasks, typically with the assistance of a Verint customer service specialist.
The available troubleshooting tasks include configuring quality of service (QoS) and
creating a serial connection in UDP.
Condition
Indication
Warmup
Red blinks (2.0 sec.
intervals)
The internal temperature of the device is too low.
Bootup
Steady red (14 sec.)
Normal operation
Flashing green (1 sec.
intervals)
The device is in normal operation.
Flashing red (1 sec.
intervals)
The IP address of the device is already assigned to
another device on the network.
Flashing green-red (1 sec.
intervals)
The device is undergoing a firmware update.
Flashing red (0.1 sec.