Verilink WANsuite 5165 Reference Manual Download Page 68

3-38

W A N s u i t e   5 1 6 5

The PPP Statistics screen provides the following user-activated buttons: 

PAP Table

At the bottom of the PPP Services Details screen are buttons that display 
tables for PAP and CHAP details. The PAP Table (Figure 3.33) displays the 
Usernames and Passwords for 10 entries. 

Figure 3.33

PAP Table Screen 

Select an Index number and click the “PAP Details” button at the bottom of 
this screen to bring up a PAP Details screen (Figure 3.34) in which you can 
view, change, or delete the Username and Password for that particular PAP 
Index. 

Figure 3.34

PAP Details Screen 

To change the Username and Password for a selected PAP Index (PAP: 1 in 
the example above), enter the new information in the appropriate fields and 
click the “Submit” button. 

Button

Function

Submit

Sets any values that have been changed.

All PPP Intervals

Opens the PPP Statistics screen that shows all statistics for all 
parameters.

Type Details

Returns you to the PPP Service Details screen.

Clear Stats

Clears all PPP statistics.

Summary of Contents for WANsuite 5165

Page 1: ...i WANsuite 5165 Reference Manual October 2002 34 00301 H...

Page 2: ...reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed...

Page 3: ...tions du Canada Safety Precautions When handling this equipment follow these basic safety precautions to reduce the risk of elec tric shock and injury Follow all warnings and instructions marked on th...

Page 4: ...iv W A N s u i t e 5 1 6 5...

Page 5: ...of the WANsuite 5165 1 3 Performance 1 3 SNMP Management 1 3 Intelligent WAN Access Architecture 1 3 Optional Advanced Network Management 1 4 About FrameStart Technology 1 4 WANsuite 5165 Overview and...

Page 6: ...1 Interface Details Button 3 22 Type Details Button 3 22 Delete Service Button 3 22 DS0 Monitor Details Screen 3 22 DS0 Status and Alarm Table 3 23 Frame Relay Service Details Screen 3 25 Status and A...

Page 7: ...Upload Save 3 90 Password 3 91 Log Out 3 92 In band Management 3 92 Use of Connected Local Router 3 92 Use of Local WANsuite 5165 as a Gateway 3 93 Chapter 4 VT100 Interface Introduction 4 1 Accessing...

Page 8: ...er Statistics Screen 4 51 SNMP Details Screen 4 52 Diagnostics Screen 4 53 Test Details Screens 4 53 Trap Log Screen 4 57 Top Talkers Screen 4 57 IP Gateway Screen 4 58 RIP Parameters 4 59 OSPF Parame...

Page 9: ...ctor Pin Assignments A 7 Serial Interface Pin Assignments for DTE Mode Packet Use Only A 7 Serial Interface Pin Assignments for DCE Mode A 8 Ethernet Connection Pin Assignments A 8 Network 1 Interface...

Page 10: ...x W A N s u i t e 5 1 6 5...

Page 11: ...ters to understand the subsequent chapters Appendices are designed to complement the main chapters Chapter 1 About the WANsuite 5165 This chapter describes product features and capabilities Chapter 2...

Page 12: ...to provide a variety of services including network planning installation hardware maintenance application training and support services When you contact your network supplier for assistance have the...

Page 13: ...eference manual is revised to reflect code changes or other updates the most recent version will be posted to the Verilink Web site Returning a Unit to Verilink If for any reason you must return your...

Page 14: ...o use when returning a unit to Verilink will be provided when the RMA is issued The standard delivery method for return shipments is Standard Ground for domestic returns and International Economy for...

Page 15: ...synchronous Supervisory port a 10 100Base T Ethernet interface and five status LEDs Capable of accommodating a wide range of network configurations the WANsuite 5165 effectively combines voice data an...

Page 16: ...transit across your network Because IP Gateway enables WANsuite to route IP traffic either statically or dynamically across your LAN WAN architecture your need for costly routers is substantially red...

Page 17: ...management enterprise managers can now manage Verilink WANsuite units and their integral CSU DSUs as a single unit With only one LAN segment in the network all Verilink WANsuite platforms can be manag...

Page 18: ...relay service is operational prior to installation and connection to other equipment FrameStart s integral frame relay circuit installation and diagnostic tools help reduce equipment and installation...

Page 19: ...e the following Offers two Network ports two Serial ports an asynchronous Supervisory port and an Ethernet port the WANsuite 5165 is extremely flexible and adapts to numerous network applications Ensu...

Page 20: ...ultiple connections to TCP clients Asynchronous multicasting lets the WANsuite 5165 transmit identical data to multiple endpoints SCADA traffic priority puts SCADA traffic in a specific queue over a f...

Page 21: ...TELNET Local Supervisory port Ethernet port for management or IP routing Frame Relay Aware Support for leased line and frame relay services Layer 2 end to end visibility and control Embedded frame re...

Page 22: ...in DTE Mode The indicator is off not illuminated when the port has not been configured The indicator lights red when DSR is not active and the configured protocol is not established The indicator lig...

Page 23: ...nfigure the unit to disable their transmission NOTICE A null modem crossover cable is required to connect a modem to the Supervisory port Data Interface Module Rear Panel The Data Interface Module DIM...

Page 24: ...that interconnecting cables carrying high speed data be shielded appropriately in order to minimize radio frequency interference Network Interfaces Labeled on the rear panel of the WANsuite 5165 as NE...

Page 25: ...for approximately 10 to15 seconds as the unit initializes The green POWER LED will remain illuminated as long as the unit receives power This LED turns amber when the unit is in test mode Power Failu...

Page 26: ...1 12 W A N s u i t e 5 1 6 5...

Page 27: ...ed from the rear of the shelf into the backplane The WANsuite 5165 front module is installed from the front The DIM is always installed first and removed last the WANsuite 5165 front module is install...

Page 28: ...t the unit must first be configured with an IP address You can configure the unit s IP address using the Verilink Configuration Wizard which is included on your documentation CD NOTICE You may also ac...

Page 29: ...the Tab key again move the cursor to the IP Address field and enter the appropriate IP address for the unit xxx xxx xxx xxx If necessary repeat this process for the Subnet Mask and Gateway Address fie...

Page 30: ...2 4 W A N s u i t e 5 1 6 5...

Page 31: ...n the navigation bar on the left side of the Web Server interface screen However because the parameters you specify in the Service Table attach protocols to interfaces you must configure the Service T...

Page 32: ...e area beneath the upper frame is divided into two side by side frames The frame on the left side of this area depicts a hierarchical tree structure used to navigate through the various interface scre...

Page 33: ...lds the unit s location FrameStart ID Read write field that holds the unit s ID that uniquely identifies the unit and is used in the FrameStart applications User Definable Fields Read write fields for...

Page 34: ...will be set back to the specified factory default Figure 3 2 Maintenance Reset Screen Save and Restart Use this button to save the current configuration settings and proceed with the restart as shown...

Page 35: ...u view and make changes to the Network interfaces configuration as described below In addition the screens provide a table that displays the alarm values for the Network interfaces All Network ports o...

Page 36: ...ul Specifies the DTE DSX 1 interface output level Values 0 110 111 220 221 330 331 440 441 550 551 660 661 ft Default 0 110 ft Framing Selects the framing for the network side of the DSU CSU Values ES...

Page 37: ...overed DS0 will be set Values As 56K 64K Default As 64K NOTICE The unit will search for active DS0s for a maximum of 7 seconds if learning As 64k and for 30 seconds if learning As 56K Error Status and...

Page 38: ...ored Seconds BPVS threshold A BPVS is a 1 second period in which at least one bipolar violation occurred The default is 0 zero seconds Disabled OOFS Sets the Out of Frame Seconds OOFS threshold An OOF...

Page 39: ...iod during which at least more than one but fewer than 320 CRC6 errors occurred Button Function Submit Sets any values that have been changed Clear Alarms Resets the alarm conditions and counts to zer...

Page 40: ...is a method of confirming the integrity of received data Beneath the Performance Current screen are two buttons Performance 24 Hour and Performance 30 Day Clicking either of these buttons will displa...

Page 41: ...ce based on its electrical signal characteristics used by the equipment connected to the Serial port Values V 35 RS 232 EIA 530 Default V 35 NOTICE V 35 requires the use of an optional cable Refer to...

Page 42: ...ied by the unit it cannot be set by the user Values Contiguous Alternate Arbitrary Default Contiguous NOTICE Because Alternate Bundling assigns every other channel only half the channels are available...

Page 43: ...Default Sync Parity Sets the parity bit Values None Odd Even Default None Stop Bit Selects the number of bits required to end the asynchronous character Values 1 2 Default 1 LL The Local Loopback para...

Page 44: ...vel of CTS to match RTS when the CTS parameter is set to Internal Values Normal 30 ms delay Long 100 ms delay Default Normal Flow Control Selects the type of flow control to be used if the port is asy...

Page 45: ...en NOTICE Always verify that a DHCP server is available on the network before enabling DHCP Client If on power up a DHCP server is not found a 60 second timeout will occur Client Identifier Displays a...

Page 46: ...n to view the Unit Access Table Figure 3 12 which specifies up to 10 different IP networks that may access the unit s parameters If no IP networks are supplied any host may access the unit Select any...

Page 47: ...00 19200 38400 57600 115200 Default 19200 Character Size Selects the number of bits required to make up one asynchronous character Values Five Six Seven Eight Default Eight Diagnostic Messages Enables...

Page 48: ...e unit to go into alarm on a loss of DTR which occurs when the Serial port detects that the DTR signal is low The DTR Status field indicates the current state of the DTR alarm Services Screen The Serv...

Page 49: ...reate a usable text file of the captured data In Analyze mode the packet switch will return the data via the Data Line Monitor Packet Table see Figure 3 17 whereas in the Live mode the Data Line Monit...

Page 50: ...ine the parameters listed above Figure 3 18 Data Line Monitor Details Screen Adding a Service To add a service begin by clicking the Add Service button on the Services screen A new service listed by t...

Page 51: ...you must supply an endpoint over which to send PPP encapsulated data and that endpoint must be for a Frame Relay DLCI In addition the Service Details screen provides the following user activated butto...

Page 52: ...on Click the Delete Service button to remove the currently configured service identified by the Service Details screen Deleting the selected service will remove all references to this service These re...

Page 53: ...on threshold in seconds above which an alarm will report Values 0 900 Default 0 Disabled End of Day Low Utilization Lets you configure as a percent what is considered low utilization at the end of the...

Page 54: ...s channel is allocated Refer to the Service Table to see how the current services are configured Idle Pattern Selects the DS0 idle pattern sent by the unit and lets the unit determine if the DS0 idle...

Page 55: ...f DS0 s Percent of DS0s utilized 1 0 100 over the period A 1 indicates an invalid value or unavailable data High Utilization sec Number of seconds 0 900 greater than or equal to the high utilization p...

Page 56: ...nagement used by the equipment connected to it If set to Auto the unit will learn the link management type and display it on the status portion of this screen Once it discovers the link management typ...

Page 57: ...rvice has two distinct transmit queues one for normal priority traffic and one for high priority traffic At this time only SCADA and TCP Server traffic are considered high priority and are placed in t...

Page 58: ...nagement DLCI If there is a DLCI entered and submitted in this field it will be the only DLCI that looks for in band management packets If a value of 0 zero is entered in this field all DLCIs will loo...

Page 59: ...e sent Status and Alarms Table The table displayed at the bottom of the Frame Relay Service Details screen reports on the status and condition of LMI parameters and on Receive Transmit alarms and thre...

Page 60: ...s and on Receive Transmit alarms and thresholds Alarm threshold levels may be changed by entering a new threshold value in the appropriate field on the Frame Relay Service Details screen and clicking...

Page 61: ...anagement octets received by the port FECN Number of Forward Explicit Congestion Notification frames received BECN Number of Backward Explicit Congestion Notification frames received Invalids Number o...

Page 62: ...menu gives you access to the configuration parameters described in the paragraphs below Figure 3 28 SCADA Details Screen Button Function Submit Sets any values that have been changed All Frame Relay I...

Page 63: ...a If set to Both the port will process all data Values Input Output Both Default Both SCADA Loopback Determines if and where SCADA will loopback received data Values None Loopback to Network Loopback...

Page 64: ...Service Details screen Figure 3 31 This menu gives you access to the configuration parameters described in the paragraphs below Figure 3 31 PPP Service Details Screen ACCM The Asynchronous Control Cha...

Page 65: ...ge Interval The time interval in seconds between CHAP challenges A value of 0 zero disables the periodic authentication challenge Values 0 3600 Default 0 disabled Initiate Negotiation Determines wheth...

Page 66: ...n Jacobsen compression Default Yes MRU Maximum Receive Units Used to inform the peer that the implementation can receive larger packets or to request that the peer send smaller packets Default Yes HDL...

Page 67: ...port Receive Frames Number of frames received by the port Octets Number of octets received by the port Mgmt Frames Number of management frames received by the port Mgmt Octets Number of management oc...

Page 68: ...screen to bring up a PAP Details screen Figure 3 34 in which you can view change or delete the Username and Password for that particular PAP Index Figure 3 34 PAP Details Screen To change the Usernam...

Page 69: ...for each of 10 entries Figure 3 35 CHAP Table Screen Select an Index number and click the CHAP Details button at the bottom of this screen to bring up a screen in which you can change the Username an...

Page 70: ...orresponding DLCIs will be saved in the configuration database only after at least one endpoint parameter has been changed and submitted in the Endpoint Details Screen on page 3 41 When in IP Gateway...

Page 71: ...N When configuring endpoints the name you assign each endpoint in the Name parameter field must be unique within the unit Service The Service Index number from the Service Table on which this DLCI was...

Page 72: ...remote WANsuite 5165 unit here This DLCI can be used for management only or for management and actual data If this parameter is set a PC connected to the LAN interface of this WANsuite 5165 can reach...

Page 73: ...ollowing paragraphs To bring up this screen click on a specific DLCI under the DLCI column on the Endpoint Table screen or on the DLCI Details button on the Endpoint Details screen Figure 3 39 DLCI De...

Page 74: ...R enforcement is configured to Yes the unit will throttle the Committed Burst down to this value when frames are received with the BECN bit set Values 0 1536000 Default 0 Discard Eligible Flag If this...

Page 75: ...technology if FrameStart Auto Discovery is enabled Round Trip Delay Size Specifies the frame size in bytes of packets making round trip If the Round Trip Delay Size is not configured the Frame Relay...

Page 76: ...R UAS Threshold Sets the Unavailable Seconds UAS alarm threshold This threshold occurs after the DLCI is unavailable for a specified number of seconds Setting this field to 0 zero disables the alarm U...

Page 77: ...Index from the pull down menu and clicking the Submit button Alternatively you can display all intervals at once by clicking the All DLCI Intervals button beneath the table The MIB ipadv2 mib describe...

Page 78: ...e Each rule is established through the Rule Details screen which is accessed by clicking on the appropriate numbered link under the Index column on the Service Aware screen The Service Aware screen Fi...

Page 79: ...desired rule configuration options and provide the appropriate filter information where required Then press the Submit button at the bottom of the screen Figure 3 43 Rule Details Screen The paragraph...

Page 80: ...right of the field see next paragraph Filter By IP Port Enables or disables filtering of the IP traffic by the IP port specified in the IP Port field Tx Alarm Threshold Specifies the threshold in bit...

Page 81: ...od Clicking on the All Traffic Meter Intervals at the bottom of the screen displays the Traffic Meter Statistics for all intervals as defined below Summary Represents the past 24 hours reports the add...

Page 82: ...SNMP traps generated by the unit The default setting is Public Trap IP Address Accepts the IP address of a network device where alarm reporting traps are to be sent Diagnostics Screen The Diagnostics...

Page 83: ...error statistics were last cleared ES Displays the number of asynchronous errored seconds that have been detected since the BERT began or since error statistics were last cleared This parameter inclu...

Page 84: ...he pattern to be transmitted during a test for the selected port Values Marks QRSS 511 2047 215 Spaces Default QRSS NOTICE The 215 pattern is the ITU European version not the ANSI version Test Duratio...

Page 85: ...nance loopback MLB Far PLB Far LLB Default No Test Loop Down Figure 3 48 Serial Interface Test Details Screen BERT Table on the Serial Interface Test Details Screen The BERT table lets you set the tes...

Page 86: ...ils Screen The Loop Table at the bottom of the screen lets you specify the type of Loop test to be performed The types of tests available for the Serial interface are shown below Loopback diagrams are...

Page 87: ...the duration parameters and desired report size in the appropriate fields and then click the Submit button Duration Establishes the amount of time in seconds for which the Top Talkers report will capt...

Page 88: ...ve been passed across it In addition the Timestamp field indicates the time at which a packet was examined for the specified IP address IP Gateway Details Screen The IP Gateway is a feature of the WAN...

Page 89: ...m those trusted neighbors will be used to build the internal routing table Values Enable Disable Default Enable RIP Interval Interval for RIP packet to be sent Default is 30 seconds RIP Domain Value r...

Page 90: ...ss this menu Figure 3 53 by accessing the appropriate numbered link under the Index column on the Circuit Table screen Button Function RIP Parameters Static Routes Table Displays static routes and dyn...

Page 91: ...t Represents the relative time of treatment of an IP packet This value is used when there are multiple routes to the same destination When two or more routes are available the one with the lowest circ...

Page 92: ...er the Hello Interval the sooner topological changes are detected but then more traffic is created Values 1 65535 Default 1 OSPF Dead Interval The number of seconds that a router s Hello s have not be...

Page 93: ...dress Represents the target network that you want this router to reach Target IP Mask Mask of the Target network Next Hop IP address of the next device in the route Cost Cost of using that route Route...

Page 94: ...o 0 0 0 0 defines THE default route for this unit Next Hop IP Address IP address of the next device in the route Cost Cost of using that route Values 0 65535 Default 1 Route Status Indicates whether o...

Page 95: ...is used by the router to dynamically associate a high level IP address to a low level physical hardware address ARP packets are only sent across a single physical network There are some cases when an...

Page 96: ...isabled The ARP Table screen provides the following user activated buttons ARP Details Screen Access this screen Figure 3 58 by clicking on the appropriate numbered link under the Index column on the...

Page 97: ...Only information coming from Trusted Neighbors is kept by the router Access this menu Figure 3 59 by selecting Trusted Neighbors from the RIP Parameters on the IP Gateway menu This table is useful wh...

Page 98: ...he ID of the Area represented by an IP address Enable Displays whether the defined Area is enabled or disabled Auth Type Indicates Area validation Stub Displays whether or not the defined area is a St...

Page 99: ...it point need not be made on a per external destination basis Values Yes No Default No Address Summary A configured address range specifies what addresses are contained within an area When summarizing...

Page 100: ...area cannot be connected directly to the backbone in this case a virtual link is used Figure 3 63 To establish or maintain the connectivity of the backbone virtual links can be configured through non...

Page 101: ...ure 3 64 Virtual Link Details Screen The Virtual Link Details screen provides the following user activated buttons TCP Server The TCP Server is a general purpose application that maps arbitrary TCP po...

Page 102: ...gure 3 66 TCP Connection Details Screen Select the TCP Connection Table to access the screen shown in Figure 3 66 This screen lets you see which addresses and ports are in a listening state and which...

Page 103: ...connect their networks to the Internet Whether on a global or local port NAT provides translation only upon receipt of a packet which NAT will translate not translate or filter depending on the user s...

Page 104: ...ired The default is NAPT Global IP Addr Global IP Address used in NAPT mode Must be a valid Class C address Default is LAN IP Address Global Mask IP Mask associated with defined Global IP Address Defa...

Page 105: ...ence Delta Timer The maximum time in seconds NAT will use resources when managing TCP Packet Sequencing Values 0 65535 Default 180 UDP Timer The maximum time in seconds NAT will use resources for a UD...

Page 106: ...is 0 Server Port Decimal IP Port of the local TCP Server This port is usually the same as the Global Port Default is 0 Server Address IP Address of the local TCP Server Default is 0 0 0 0 The Static T...

Page 107: ...t is 0 Server Address IP Address of the local UDP Server Default is 0 0 0 0 The Static UDP Translation Table screen provides the following user activated buttons You can configure or change the above...

Page 108: ...ination address different from the global Internet network address will be processed by the IP Gateway and may be routed to another port If this parameter is set to Disable no packet with a destinatio...

Page 109: ...nfiguration Protocol DHCP DHCP provides a mechanism through which computers using TCP IP can obtain protocol configuration parameters automatically through the network The most important configuration...

Page 110: ...vention from a centrally managed DHCP server DHCP is available on the 10 100 Ethernet port only NOTICE You must Save and Restart for any changes in DHCP configuration parameters to take effect NOTICE...

Page 111: ...t is 0 0 0 0 Secondary DNS IP Addr If requested by DHCP client the client then uses this secondary address to resolve names of IP addresses Default is 0 0 0 0 The DHCP Server Details screen provides t...

Page 112: ...IP address will always be used for a given PC provided its MAC address is known These parameters are configured on the Static Entry Details screen Figure 3 82 accessed by selecting a numbered link fr...

Page 113: ...addresses available for DHCP clients These parameters are configured on the IP Address List Details screen Figure 3 84 accessed by clicking on a numbered link in the Index column Figure 3 83 IP Addres...

Page 114: ...tivated buttons IP Address Status Table Screen The IP Address Status Table screen Figure 3 85 displays a list of all current DHCP clients Figure 3 85 IP Address Status Table Screen MAC Address MAC Add...

Page 115: ...ly forward packets from one network to others however Rather it learns all local physical addresses and forwards packets based on those learned tables This greatly reduces the number of broadcasted pa...

Page 116: ...ult 300 s The Bridge Details screen provides the following user activated buttons Figure 3 87 Bridge Port Table The Bridge Port Table screen lets you view the parameters described below the Bridge Por...

Page 117: ...this port The lower the value the higher the priority Path Cost Value of efficiency of the path to the port A higher path cost indicates a slower link State If Enabled reflects the state of the port...

Page 118: ...own MAC address and Learned the unit learned MAC address is directly accessible by this port Simple Mail Transfer Protocol SMTP Use the SMTP Details Screen Figure 3 90 to configure the SMTP function o...

Page 119: ...ress Recipient 1 5 E mail addresses of recipients of event notifications i e sales verilink com or support verilink com Encryption If a DLCI encapsulation is set for FRF 17 instead of RFC1490 all data...

Page 120: ...ou allow sufficient time for the download to occur Canceling the download before it has fully executed will result in the new software NOT being installed into the unit Upload Save The Upload Save scr...

Page 121: ...d are digits 0 9 and letters A Z and a z for a total of 62 distinct characters Figure 3 93 Password Screen To change either the Admin or Read Only password you must enter it once in the New Password f...

Page 122: ...ent remote in band management of a WANsuite 5165 unit The first is to use the local router to route management frames Web browser or SNMP between the local LAN and the remote unit The second is to use...

Page 123: ...ddress assignment is also independent from the routers The PC used for management must have the local WANsuite 5165 s IP address as its gateway address so that it can reach all remote WANsuite 5165s F...

Page 124: ...3 94 W A N s u i t e 5 1 6 5...

Page 125: ...port or remotely through a TELNET session To access the VT 100 screens locally verify the Supervisory type is tty and the Supervisory port speed matches the terminal emulation program that s being use...

Page 126: ...mmands is provided Perform each command by pressing a letter key while holding down the Ctrl key You may use the alternative commands shown in the following table and keyboard commands interchangeably...

Page 127: ...be replaced by the new characters To edit an existing entry rather than replace it press the right arrow key to move the cursor to the point that needs editing You may insert characters or delete them...

Page 128: ...Location Read write field that holds the unit s location FrameStart ID Read write field that holds the unit s ID that uniquely identifies the unit and is used in the FrameStart applications Blank Fiel...

Page 129: ...ing the space bar you may toggle through the options to select the desired maintenance reset Default TDM Configuration Default Packet Configuration Default Packet 2 Configuration Default Packet 3 Conf...

Page 130: ...sing Ctrl U after approximately 10 seconds to restore communications Save and Restart Selecting Save and Restart will display a confirmation menu similar to that shown in Figure 4 4 Select yes to save...

Page 131: ...nfig Screen Function Network 2 Only In the Slaved function Network 2 is slaved and can only be mapped to Network 1 In the Network function Network 2 functions as an independent network but can only be...

Page 132: ...ng source to synchronize the unit s internal timing generators In all cases slips are controlled to occur on frame boundaries at the Network ports when timing synchronization is lost The options are a...

Page 133: ...able alarm reporting set all fields to 0 zero The 15 minute time frame is not based on the TR 54016 or T1 403 interval boundaries but is a time window based on the accumulated counts over the previous...

Page 134: ...he terminal equipment when an improper signal is received from the facility or upon receipt of unframed all ones The default is 0 seconds Disabled Reset Timer The status table also provides an option...

Page 135: ...ES A Bursty Error Seconds BES is a 1 second period during which at least more than one but fewer than 320 CRC6 errors occurred LOFC The Loss of Frame Count LOFC represents the number of time a loss of...

Page 136: ...directly to the WANsuite 5165 s Data 1 and Data 2 ports respectively The Serial screens let you view and make changes to the unit s Serial interface configuration as described in the paragraphs below...

Page 137: ...the Serial port connects to a DTE device such as a FRAD or a router the Mode parameter must be set to DCE If this port connects to a DCE device such as a DSU CSU this parameter must be set to DTE vali...

Page 138: ...Rate Channel Rate The unit can operate at any data rate that is a multiple of 56 or 64 kbps If x64K is selected the ones density requirements of the T1 network line must be ensured If x56K is selected...

Page 139: ...ccurs when the Serial port detects that the DTR signal is low Values Enable Disable Default Disable DTR Alarm Status Lets you view the current DTR Alarm status Format Selects the port s operating mode...

Page 140: ...parameter determines the source from which the unit reads the RTS signal status If set to Normal the unit gets RTS from the DTE on the Serial interface If set to Forced True RTS is always perceived as...

Page 141: ...ier for a specific IP address Ethernet Enables or disables a remote unit s Ethernet port Physical Address Displays unique MAC address NOTICE Always verify that a DHCP server is available on the networ...

Page 142: ...rts only asynchronous character formats Figure 4 14 Supervisory Configuration Screen The Supervisory screen lets you view and change the Supervisory port speed The Supervisory port only supports async...

Page 143: ...ault Disable DTR Alarm Status Lets you view the current DTR Alarm status Diagnostic Messages Enables the Supervisory port to send out diagnostic messages upon power up Values Enable Disable Default En...

Page 144: ...otiations Up The service is ready to pass data Idle The service has nothing to do The Service Table screen displays the available services listed by Index number To view more detailed information abou...

Page 145: ...d and captured Pattern Displays which specific pattern is being searched for Mask Displays the bits the unit is looking for Offset Displays the offset in the packet that matches the pattern You may vi...

Page 146: ...the Data Line Monitor Packet Table whereas in the Live mode the Data Line Monitor Packet Table will appear empty for SNMP calls Buffer Management Displays whether displayed data is set to Wrap or Stop...

Page 147: ...ual interface you must supply an endpoint over which to send PPP encapsulated data and that endpoint must be for a Frame Relay DLCI Type Selecting one of the services listed under the Type column will...

Page 148: ...econds that an alarm condition must not be present before an alarm is reset Zero 0 indicates the Alarm Reset Timer is disabled Values 0 900 Default 30 High Utilization Lets you configure as a percent...

Page 149: ...kbps Values 56K 64K Default 64K Service Specifies the service to which this channel is allocated Refer to the Service Table to see how the current services are configured Idle Pattern Selects the DS0...

Page 150: ...history is displayed Timestamp System up time value during which the utilization historical period was completed Utilization of DS0 s Percent of DS0s utilized 1 0 100 over the period A 1 indicates an...

Page 151: ...the user side of a User to Network interface If it is connected to a FRAD router the Interface Type should be set to NI as it is the network side of a User to Network interface If it is connected to...

Page 152: ...r of link reliability and protocol errors that can occur during the sliding event monitor count defined by N3 If this count is exceeded the port is declared inactive Values 1 255 Default 3 N3 This cou...

Page 153: ...ult 0 Enforce CIR and Be If this parameter is set to Yes the unit will enforce Committed Information Rate and Excess Burst according to the Link Injection Parameter Values No Yes Default No NOTICE The...

Page 154: ...one for high priority traffic At this time only SCADA and TCP Server traffic are considered high priority and are placed in the high priority queue All other types of traffic are placed in the normal...

Page 155: ...elay Statistics prompt to bring up a table Figure 4 25 that reports on the status and condition of LMI parameters and on Receive Transmit alarms and thresholds Alarm threshold levels may be changed by...

Page 156: ...elay Port Statistics Screen Transmit Frames Number of frames transmitted by the port Octets Number of octets transmitted by the port Mgmt Frames Number of management frames transmitted by the port Mgm...

Page 157: ...eived in frame relay LMI status inquiries Stat Responses Number of octets received in frame relay LMI status responses Invalid LMIs Number of invalid Local Management Interface frames received Through...

Page 158: ...Default 192 168 1 3 Virtual PPP Over Endpoint name over which to send PPP encapsulated data i e PPP over Frame Relay Valid only when the PPP interface is Virtual Auth Challenge Interval The time inter...

Page 159: ...ression Compresses PPP protocol headers Default Yes IPCP Compression Compresses TCP headers using Van Jacobsen compression Default Yes MRU Informs the peer that the implementation can receive larger p...

Page 160: ...tets transmitted by the port Rx Frames Number of frames received by the port Rx Octets Number of octets received by the port Average Average bandwidth in bps used by the port Peak Peak bandwidth in bp...

Page 161: ...elete the Username and Password for a selected PAP Index delete the character string displayed in both fields leaving them blank and press the Esc key CHAP Table From the PPP Service Details screen se...

Page 162: ...listed below Figure 4 31 SCADA Service Details Screen Message Size Maximum number of characters to buffer before sending a frame Values 0 1024 Default 256 Idle Character Delay Maximum number of idle...

Page 163: ...all SCADA statistics by selecting the SCADA Clear Statistics prompt at the bottom of the screen Select the SCADA Device List prompt to bring up a screen that shows the mapping between SCADA devices an...

Page 164: ...cs for Layer 3 and above that do not map to a specific service or interface Figure 4 34 Applications Screen Endpoint Table Screen The Endpoint Table Figure 4 35 describes all endpoints terminating in...

Page 165: ...A Sn are reserved by the system These system generated endpoints cannot be modified Figure 4 35 Endpoint Table Screen You can add an endpoint in the Add Endpoint field and when the screen refreshes yo...

Page 166: ...onfiguring endpoints the name you assign each endpoint in the Name parameter field must be unique within the unit Service This is the Service Index number from the Service Table on which this DLCI was...

Page 167: ...te WANsuite 5165 unit here This DLCI can be used for management only or for management and actual data If this parameter is set a PC connected to the LAN interface of this WANsuite 5165 can reach a re...

Page 168: ...ement RFC 1490 must be the encapsulation method Protocol Encapsulation This is the type of encapsulation used by the FRAD router connected to the unit Values RFC 1490 Proprietary Default RFC 1490 Prop...

Page 169: ...e the unit will send FrameStart discovery and delay frames on this DLCI and will report the state of the remote Verilink unit with FrameStart technology It will also send SOS frames when the FRAD rout...

Page 170: ...CN BECN When a frame is received with congestion bit set this parameter is set to Yes It is set back to No when a frame is received without congestion bit set Values Yes No Default No CIR Threshold Se...

Page 171: ...DLCI statistics If the unit is powered on at 01 00 PM the first interval will be completed at 01 15 PM subsequent intervals would be completed at xx 30 xx 45 xx 00 and xx 15 Interval 1 is always the l...

Page 172: ...fers to Frame Delivery Ratio which is the ration of successful frame receptions to attempted frame transmissions DDR refers to Data Delivery Ratio or the ratio of successful payload bytes received to...

Page 173: ...rough the Rule Config screen which is accessed by selecting Rule Details The Service Aware screen Figure 4 41 provides a table showing these filtered packet counts for up to 10 rules This table indica...

Page 174: ...e rule applies Filter By DLCI Enables or disables filtering of the IP traffic in accordance with the previously specified DLCI NOTICE To use this filter you must specify both the Service and DLCI para...

Page 175: ...f frames and octets sent over a DLCI that have been counted in accordance with the Service Aware rule that has been established for a Service As such it is frame relay specific i e DLCIs only occur in...

Page 176: ...as many as eight destinations on your network The unit will report each alarm by transmitting an SNMP trap to each non zero Trap IP address The SNP Details screen Figure 4 44 lets you configure the S...

Page 177: ...p Type Describes the type of loop test if any performed on the selected interface Setting Displays the bandwidth on which you wish to perform the BERT Pattern Specifies the pattern to be transmitted d...

Page 178: ...he ANSI version Test Duration Specifies the length of time for which the test should run for the selected port Values 15 minutes 30 minutes 1 hour 24 hours Continuous Default 15 minutes From this scre...

Page 179: ...divided by the number of seconds accumulated in Elapsed Time Loop Table on Network Interface Test Details Screen The Loop Table at the bottom of the screen lets you specify the type of Loop test to b...

Page 180: ...splays the total number of bit errors detected since the test began or since error statistics were cleared Errored Seconds Displays the number of asynchronous errored seconds that have been detected s...

Page 181: ...error captured by the trap Trap Number and the date and time that the trap was stored Time Stamp Figure 4 48 Trap Log Screen Top Talkers Screen Selecting Top Talkers displays the Top Talkers screen F...

Page 182: ...ys the actual number of IP addresses identified as Top Talkers in the generated report The maximum report size is 20 Start Time Displays the time at which the Top Talkers report was initiated based on...

Page 183: ...esses required Figure 4 50 IP Gateway Screen RIP Parameters RIP Enable Globally enables RIP1 RIP2 or No RIP Default is RIP 2 Values Disable Enable RIP1 Enable RIP2 Default Enable RIP2 RIP Trust Neighb...

Page 184: ...nique router ID Default is the LAN IP address of the unit The IP Gateway screen provides the following user prompts that may be selected by pressing the Enter key Circuit Table Screen This menu shows...

Page 185: ...k of the circuit Max Transmit Unit Maximum transmit unit this circuit will send at any one time Cost Represents the relative time of treatment of an IP packet This value is used when there are multipl...

Page 186: ...ame network The smaller the Hello Interval the sooner topological changes are detected but then more traffic is created Values 1 65535 Default 1 OSPF Dead Interval The number of seconds that a router...

Page 187: ...the configuration parameters of a given route Figure 4 54 Route Details Screen Field Description Endpoint Endpoint name or interface through which to send the IP packet to reach the Target IP Address...

Page 188: ...or disabled Dynamic Route Table Screen Access this menu by selecting the Static Route Table on the IP Gateway menu and then selecting Dynamic Route Table This table shows all known dynamic and static...

Page 189: ...te a Static ARP Table entry because an ARP entry is always associated with a circuit The static ARP table is useful when a Host does not respond to an ARP request Access this menu by selecting Static...

Page 190: ...00 00 00 00 00 00 ARP Status Displays whether this static ARP is enabled or disabled Values Enable Disable Default Enable Trusted Neighbors Screen The Trusted Neighbors feature can be used to store RI...

Page 191: ...Index column This screen lists all IP addresses of Trusted Neighbors Figure 4 59 Neighbor Details Screen Area Table Screen An Area allows growth and makes the networks at a site easier to manage An ar...

Page 192: ...ils Screen Field Description Area ID Displays the ID of the Area represented by an IP address Ena Displays whether the defined area is enabled or disabled Auth Type Indicates Area validation Stub Disp...

Page 193: ...Mask of the summary to be added Values 0 0 0 0 255 255 255 255 Default 0 0 0 0 Advertise Describes the local state of a router or network This includes the state of the route s interfaces and adjacenc...

Page 194: ...defined by the following two parameters The Router ID of the virtual link s other endpoint The non backbone area across which the virtual link goes through Figure 4 62 Virtual Link Table Screen The fi...

Page 195: ...ze on page 4 30 for more details The TCP Server is a general purpose application that maps arbitrary TCP port numbers to non TCP IP devices that have been assigned an endpoint See the Endpoint Table S...

Page 196: ...e TCP Connection Table prompt on the TCP Server screen to access the screen shown in Figure 4 66 This screen lets you see which addresses and ports are in a listening state and which are already estab...

Page 197: ...sers cost effectively and efficiently connect their networks to the Internet Whether on a global or local port NAT provides translation only upon receipt of a packet which NAT will translate not trans...

Page 198: ...d to a Class C public address on the Global side In other words if there are 30 hosts on the private Local side 30 public Global addresses are required The default is NAPT Global IP Addr Global IP Add...

Page 199: ...hen attempting to close a TCP connection Values 0 65535 Default 0 TCP Disconnected Timer The maximum time in seconds NAT will use resources when attempting to disconnect from TCP Values 0 65535 Defaul...

Page 200: ...Default is 0 Server Port Decimal IP Port of the local TCP Server This port is usually the same as the Global Port Default is 0 Server Address IP Address of the local TCP Server Default is 0 0 0 0 The...

Page 201: ...Screen Enable Enables or disables the NAT port Default is Enable Default Translation Forces translation on a specific IP port regardless of the source IP Address If Default Translation is set to Enabl...

Page 202: ...ss Default is the value defined in the IP Gateway Circuit Table Endpoint The Endpoint name of the circuit associated with the LAN or WAN port Default is LAN for the first port The Add New prompt lets...

Page 203: ...igure 4 75 allows static mapping of global UDP Server ports to a local host IP address port combination The parameters described below enable access to UDP Servers on the private corporate network beh...

Page 204: ...computer is attached and that is not assigned to any other computer on that network If a computer moves to a new network it must be assigned a new IP address for that new network DHCP can be used to m...

Page 205: ...ed amount of time to ensure the IP address is not given to another PC Default is 600 seconds Primary DNS IP Addr If requested by DHCP client the client then uses this address to resolve names of IP ad...

Page 206: ...ost name NOTICE You must Save and Restart for the new Server name to become active Static Entries Screen The Static Entries screen Figure 4 79 lists static IP addresses associated with MAC addresses T...

Page 207: ...efined on this screen Mask Mask associated with the IP Address shown on the screen Host Name Name given to the DHCP client Select Add New to add a static entry IP Address List Screen The IP Address Li...

Page 208: ...this screen Status Provides IP Address Status Bridge A Bridge operates at the physical network layer connecting two or more networks and forwarding packets between those networks For example a Bridge...

Page 209: ...s the group address for the Bridge Protocol Data Unit BPDU transfer between bridges Values Any valid Group Multicast MAC Address Default 0180C2000000 Bridge ID Consists of a bridge priority and its ow...

Page 210: ...ble prompt displays the screen shown below in Figure 4 83 Selecting a number in the Index column of the Bridge Port Table will bring up the Bridge Port Details screen Figure 4 84 which displays and in...

Page 211: ...rity associated with this port The lower the value the higher the priority Path Cost Value of efficiency of the path to the port A higher path cost indicates a slower link State If Enabled reflects th...

Page 212: ...s How the address was included in the forwarding table The two possibilities include Self the unit s own MAC address and Learned the unit learned MAC address is directly accessible by this port Simple...

Page 213: ...lled in NOTICE There can be no blank space s in the Mail From address Recipient 1 5 E mail addresses of recipients of event notifications i e sales verilink com or support verilink com Encryption If a...

Page 214: ...4 90 W A N s u i t e 5 1 6 5 Figure 4 87 Encryption Details Screen...

Page 215: ...protection fused input output Jitter Control per TR 62411 and T1 403 Timing Source With Function parameter on Network 2 screen in Slaved mode options are Internal Network 1 Network 2 Serial 1 Serial...

Page 216: ...ps where n 1 32 or nx56 kbps where n 1 31 or Asynchronous 1200 2400 4800 9600 19200 38400 57600 115200 bps Clocking Internal External Management Interfaces 10 100 Ethernet Connection 8 pin modular Net...

Page 217: ...Network Framer Port Logic Nx64 Port LLB WANsuite 5165 Internal Logic Network Port T1 Network Framer Port Logic Nx64 Port PLB WANsuite 5165 Internal Logic Network Port T1 Network Framer Port Logic Nx6...

Page 218: ...5 2 ounces 430 91 grams Environmental Operating Temp 32 to 122 F 0 to 50 C Storage Temp 4 to 149 F 20 to 65 C Humidity 95 maximum non condensing Frame Relay Statistics Collected in 96 15 minute Interv...

Page 219: ...es Tx Rx mgmt octets Rx invalid frames Peak average throughput Industry Listings FCC Compliance Part 15 Class A Subpart B Part 68 U S Safety UL 1950 3rd edition Canadian Safety CSA C22 2 No 950 95 Ind...

Page 220: ...Serial Supervisory Cable RJ 11 to DB 9 WANsuite Documentation CD Description Serial DCE Cable DB 25 DB 25 M M pin pin EIA 530 RS 232 6 ft Serial DCE Cable DB 25 Winchester 34 pin V 35 M M pin pin 5 f...

Page 221: ...7 B 7 Data Carrier Detect DCD Input 8 8 F 8 Balanced Receiver Clock B RC Input 12 X 9 Balanced Data Carrier Detect B DCD Input 10 10 Balanced External Transmitter Clock B ETC Balanced Transmitter Clo...

Page 222: ...Data Carrier Detect DCD Output 8 8 F 8 Balanced Receiver Clock B RC Output 9 X 9 Balanced Data Carrier Detect B DCD Output 10 10 Balanced External Transmitter Clock B ETC Input 11 W 11 Balanced Transm...

Page 223: ...ays the pinout assignments Supervisory Port Pin Assignments The LOCAL Supervisory port interface is a standard RJ 11 6 pin modular jack The table below displays the pinout assignments 3 Data In 6 Data...

Page 224: ...A 10 W A N s u i t e 5 1 6 5...

Page 225: ...ss write access and trap access the community string sent with an SNMP trap Configuration of these community strings within the WANsuite 5165 is accomplished via the HTTP web browser interface refer t...

Page 226: ...Relay PPP and Service Aware configuration and statistics ipstart mib MIB module for synchronous PPP Monitor router mib provides configuration of OSPF router hdsl2 mib MIB module for HDSL ipaddhcp mib...

Page 227: ...m the notPresent state This other state is indicated by the included value of ifOperStatus ifIndex ifAdminStatus ifOperStatus linkUp snmpTraps 4 A linkUp trap signifies that the SNMP entity acting in...

Page 228: ...a higher level line status change i e ds3 then no traps for the ds1 are sent dsx1LineStatus dsx1LineStatusLastChange frDLCIStatusChange frEnterprise 1 This trap indicates that the indicated Virtual C...

Page 229: ...hdsl2ShdslPerfESThreshTrap 3 This trap indicates that the errored seconds threshold as per the hdsl2ShdslEndpointThreshES value has been reached exceeded for the HDSL2 SHDSL segment endpoint identifi...

Page 230: ...fNumRepeaters hdsl2ShdslLoopbackFailure 9 This trap indicates that an endpoint maintenance loopback command failed for an HDSL2 SHDSL segment ifIndex hdsl2ShdslInvIndex hdsl2ShdslEndpointSide hdsl2Shd...

Page 231: ...NeighborPresent in the hdsl2ShdslEndpointCurrStatus object for this endpoint has changed ifIndex hdsl2ShdslInvIndex hdsl2ShdslEndpointSide hdsl2ShdslEndpointWirePair hdsl2ShdsllocalPowerLoss 16 This t...

Page 232: ...old is the number of frames in excess of Be ipadDLCItxExBeAlarm ipadDLCIRxCongestionExceeded 25005 This trap is sent out when the Rx congestion threshold has been exceeded This threshold is the number...

Page 233: ...n SOS condition ipadDLCIremoteEquipActive ipadDdsLOSSAlarmDeclared 25020 This trap is sent out when a Loss of Signal Seconds alarm is declared ddsNetLOSCount ipadDdsOOFSAlarmDeclared 25021 This trap i...

Page 234: ...files for Castle Rock Computing s SNMPc 2 Start the SNMP manager if it is not already running Select one of the menu selections or selection subheadings that contains the SNMP MIB operations this is O...

Page 235: ...ED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT WILL VERILINK S LIABILITY TO BUYER OR ANY SUCCESSOR TO BUYER EXCEED THE PRICE PAID FOR THE APPLICABLE GOODS IV LIMITED WARRANTY CONDITIONS The Limited...

Reviews: