![Verilink WANsuite 5165 Reference Manual Download Page 162](http://html1.mh-extra.com/html/verilink/wansuite-5165/wansuite-5165_reference-manual_1004291162.webp)
4-38
W A N s u i t e 5 1 6 5
To change the Username and Secret for a selected CHAP Index, enter the new
information in the appropriate field(s) and press the “Esc” key.
SCADA Service Details Screen
NOTICE:
SCADA traffic has a higher priority than other types of traffic flowing
through the unit. Refer to Normal Tx Queue Size on page 4-30 for more
details.
The SCADA Service Details screen (Figure 4.31) lets you access and read or
change the parameters described in the paragraphs listed below.
Figure 4.31
SCADA Service Details Screen
Message Size
Maximum number of characters to buffer before sending a frame.
Values: 0
−
1024
Default: 256
Idle Character Delay
Maximum number of idle character time to wait before sending a frame.
Values: 0
−
65535
Default: 10
Input Terminator
Decimal value of the character that terminates a message before sending a
frame.
Values: 0
−
255
Default: 0
Data Direction
Data direction that the port will support. If set to “Input,” the port will only
accept incoming data and will not transmit data. If set to “Output,” the port
will ignore any incoming data. If set to “Both,” the port will process all data.
Values: Input, Output, Both
Default: Both
Summary of Contents for WANsuite 5165
Page 1: ...i WANsuite 5165 Reference Manual October 2002 34 00301 H...
Page 4: ...iv W A N s u i t e 5 1 6 5...
Page 10: ...x W A N s u i t e 5 1 6 5...
Page 26: ...1 12 W A N s u i t e 5 1 6 5...
Page 30: ...2 4 W A N s u i t e 5 1 6 5...
Page 124: ...3 94 W A N s u i t e 5 1 6 5...
Page 214: ...4 90 W A N s u i t e 5 1 6 5 Figure 4 87 Encryption Details Screen...
Page 224: ...A 10 W A N s u i t e 5 1 6 5...