W e b S e r v e r I n t e r f a c e
3-33
Message Size
Maximum number of characters to buffer before sending a frame.
Values: 0
−
1024
Default: 256
Idle Character Delay
Maximum number of idle character time to wait before sending a frame.
Values: 0
−
65535
Default: 10
Input Terminator
Decimal value of the character that terminates a message before sending a
frame.
Values: 0
−
255
Default: 0
Data Direction
Data direction that the port will support. If set to “Input,” the port will only
accept incoming data and will not transmit data. If set to “Output,” the port
will ignore any incoming data. If set to “Both,” the port will process all data.
Values: Input, Output, Both
Default: Both
SCADA Loopback
Determines if and where SCADA will loopback received data.
Values: None, Loopback to Network, Loopback to Port
Default: None
The table below these parameters displays the SCADA statistics.
The SCADA Details screen provides the following user-activated buttons:
Figure 3.29
SCADA Device Table Screen
Select the appropriate numbered link under the “Device” column to access the
SCADA Device Details screen (Figure 3.30) where you can map SCADA
devices to endpoints.
Button
Function
Submit
Sets any values that have been changed.
SCADA Device List
Displays a table that shows the mapping between
SCADA devices and endpoints
.
Clear SCADA Statistics
Clears all SCADA statistics.
Summary of Contents for WANsuite 5165
Page 1: ...i WANsuite 5165 Reference Manual October 2002 34 00301 H...
Page 4: ...iv W A N s u i t e 5 1 6 5...
Page 10: ...x W A N s u i t e 5 1 6 5...
Page 26: ...1 12 W A N s u i t e 5 1 6 5...
Page 30: ...2 4 W A N s u i t e 5 1 6 5...
Page 124: ...3 94 W A N s u i t e 5 1 6 5...
Page 214: ...4 90 W A N s u i t e 5 1 6 5 Figure 4 87 Encryption Details Screen...
Page 224: ...A 10 W A N s u i t e 5 1 6 5...