BERT Pattern
Specifies the pattern to be transmitted during a test for the selected port.
Values: Marks, QRSS, 511, 2047, 2^15, Spaces
Default: QRSS
NOTICE:
The 2^15 pattern is the ITU (European) version, not the ANSI version.
Test Duration
Specifies the length of time for which the test should run for the selected port.
Values: 15 minutes, 30 minutes, 1 hour, 24 hours, Continuous
Default: 15 minutes
You can also view the following read-only parameters from this screen:
Pattern Sync
Displays the state of pattern sync during a test. If no test is in progress, “No
Test” is displayed. If a test is active, but the receiver is not in pattern sync,
“No Sync” is displayed. If the receiver is in pattern sync, “In Sync” is
displayed.
Elapsed Time
Displays the time elapsed since a timed test began or, if completed, the total
test time.
Bit Errors
Displays the total number of bit errors detected since the test began or since
error statistics were cleared.
Errored Seconds
Displays the number of asynchronous errored seconds that have been detected
since the test began or since error statistics were last cleared.
%EFS
Displays the percentage of time the test ran error-free. This ratio is derived
from the number of error free seconds divided by the number of seconds
accumulated in Elapsed Time.
Loop Table on Serial Interface Test Details Screen
The Loop Table at the bottom of the screen lets you specify the type of Loop
test to be performed. The types of tests available for the Serial interface are
shown below. Loopback diagrams are illustrated in Appendix A, Figure A.1.
Values: No Test, Port Loop, V.54 Loop, Far V.54 Loop
Default: No Test (Loop Down)
The Test Details screens provide the following user-selectable prompts:
Prompt
Function
Start BERT
Starts the specified BERT.
Stop BERT
Stops the currently running BERT.
Error Inject
Injects a bit error.
Reset Errors
Resets the current error count.
Summary of Contents for WANsuite 5165
Page 1: ...i WANsuite 5165 Reference Manual October 2002 34 00301 H...
Page 4: ...iv W A N s u i t e 5 1 6 5...
Page 10: ...x W A N s u i t e 5 1 6 5...
Page 26: ...1 12 W A N s u i t e 5 1 6 5...
Page 30: ...2 4 W A N s u i t e 5 1 6 5...
Page 124: ...3 94 W A N s u i t e 5 1 6 5...
Page 214: ...4 90 W A N s u i t e 5 1 6 5 Figure 4 87 Encryption Details Screen...
Page 224: ...A 10 W A N s u i t e 5 1 6 5...