Draft 3
Printed: 09/07/2003
Page 9
doc: icu_kit_user_maunul_090703.doc
3.0 Using Wireless Remote Controllers with the ICU system
The System can be “
Full set
”, “
Part set 3
” and “
day / unset
” with the wireless remote controls, they can
also act as wireless remote “
PA
” Buttons. Up to 3 Remote Controllers can be programmed into the ICU
Freedom Control unit. The wireless remote control unit can not reset a PA alarm that has been activated, to
reset the system it must be done via the on board keys pad.
When any button is pressed on the wireless remote control the LED will flash showing a button has been
pressed.
3.1 Setting and Un-setting the System
3.1.1 Full Setting / Arming
Quick Key Sequence
Press
exit premises
Detailed Explanation
Press the following keys:
Press
Exit countdown commences and the control unit beeps slowly displays shows
“
F u
”
flashing.
During the last 10 seconds of the exit countdown, the beeping gets faster as a final
warning to leave the premises.
Once armed, the display on the control unit will go blank and the external strobe will
activate for 5 seconds confirming the system has set after you have left the
premises.
If the user attempts to set the system while any zones are open the control unit will provide a bad bleep
and return to day mode, to set the system ensure all windows and doors closed and set the system.
During the exit timer if any “Entry / Exit” zones or “walkthrough” zones are triggered they will be ignored, if
any instant zones are triggered the alarm system will activate a local alarm and sound the internal
sounders, to silence the alarm the code will need to be entered to cancel the activation.
Exit timer is factory set at 30 seconds.
LED
Full Set Button
Part Set Button
Unset Button
ICU WIRELESS REMOTE CONTROL
F
F
F
P
U
PA Feature