Programming Manual
GLASSFRONT VENDING MACHINES
Rev. 1.12
MODELLS: G-DRINK SVE GF6 / GF9 – DR6 / DR9
Page 18 of 42
C5
RESET COUNTER MODE
This parameter determines the MIS internal counter reset methode:
C5 = 0 All resettable counter will be reset only using a reset command on
MIS communication mode (default).
C5 = 1 All resettable counter will be reset when you open the door, read one
of the resettable counter and close the door.
C5
RESET COUNTER MODE (From Version V 1.40)
C5 = 0 All resettable counter will be reset only using a reset command on
MIS communication mode (default).
C5 = 1 All resettable counters will be reset after each DEX reading.
C6
SOLD-OUT MODE FOR SNACK SLAVE UNIT
This parameter is used to enable sold-out status of a selection when the optical
barrier does not detect a product.
The sold-out status is reset when the door switch of the master is actuated.
C6 = 0 selection always available
C6 = 1 selection inhibited if "empty" was detected by the previous vend
C7
SAVE CREDIT MODE
This parameter determines how the VMC have to manage the credit:
C7 = 0 Clear the credit if nothing happens in the last five minutes (default).
C7 = 1 Keep the credit indefinitely.
C8
FORCED VEND
This parameter is used to prevent the use of the machine as a coin changer. When forced
vend is enabled you can obtain escrow only in the following cases:
- If coins are inserted and a selection is made (full or empty selection is the same).
- If you insert a coin that you can obtained through escrow (coins that go to the tube of
the coinage) and you don’t reach the maximum price.
C8 = 0 Forced vend disabled (default)
C8 = 1 Forced vend enabled.
Note: If a cashless system with reload facility is used Forced Vend is automatically disabled.