VELBUS INSTALLATION GUIDE
©2015 Velbus
57
www.velbus.eu
Press “Done” to exit the dialog.
After synchronization > write, you will now be able to access from the
VMBGPOD glass panel’
s display
both the “Living” and the “Bathroom”
thermostat functions. These include setting the mode (anti-freeze, night, day,
or comfort) and changing the current target temperature. This change can be
timed (e.g. 2° warmer for one hour) or it can remain active until the next
program step or the next manual intervention. (Please refer to the product and
FAQ pages on
4. Create connections
Finally, we need to create the right connections (actions) between the
temperature sensors and the relay channels controlling the heating system.
How the Velbus relays need to be physically connected to the heating system
depends on the specific system. A standard setup could be, for instance, one
relay commanding the central pump of the heating system, and for each
heating circuit a separate relay channel that controls the flow valve.
Summary of Contents for VMB4RYLD
Page 1: ...Installation Guide ...
Page 2: ...v 2015 08 04 ...