Power loss
In case of power loss, inhibit and forced statuses may be lost. To make sure
they are automatically activated when power is restored, use a (virtual)
normally closed input channel (e.g. a push button) to set these statuses. When
power comes up, this input channel will close immediately and make sure the
installation starts up in the correct state.
CONFIGURING MODULES
All addressable Velbus modules have settings that can be configured. These
vary depending on the type of module. Relay channels for instance can be set
to
“
normally closed
”
or
“
normally open
”
. For input buttons the array of
possible settings is much wider: the response time can be set, single/dual/multi
mode can be chosen, LED indication and backlights can be configured, program
steps can be added, and so on. In glass panels, additionally the thermometer
and thermostat functions can be configured, display settings can be edited, and
so on. For dimmers the operation mode may be configurable, multi step
presets can be set, and so on.
To access the configuration dialog of a module, select the module in the
navigator and click on the gear icon . In the example below, we opened the
configuration dialog of a VMBGPOD module.