45
synthesis
Un140
Main loop bus voltage
0~0xFFFF
V
0xE140
Un141
Effective value of current feeDBack
0~0xFFFF
0.01A
0xE141
Un14B
D axis current command monitoring
0~0xFFFF
%
0xE14B
Monitorin
g code
Monitor name
Range
Company
Postal
address
Un220
Torque command voltage (uncorrected)
0~0xFFFF
mv
0xE220
Un221
Torque command voltage (after correction)
0~0xFFFF
mv
0xE221
Un222
Speed command voltage (not corrected)
0~0xFFFF
mv
0xE222
Un223
Speed command voltage (after correction)
0~0xFFFF
mv
0xE223
Un300
Current alert code
0~0xFFFF
-
0xE300
Un301
Last warning code
0~0xFFFF
-
0xE301
Un302
Timestamp when the alarm occurred
0~0xFFFFFFFF
100ms
0xE302
Un303
Rotation speed of motor when alarm occurs
0~0xFFFF
rpm
0xE303
Un304
Speed command when alarm occurs
0~0xFFFF
rpm
0xE304
Un305
Internal torque command during alarm
occurrence
0~0xFFFF
%
0xE305
Un306
Input instruction pulse speed when alarm
occurs
0~0xFFFF
rpm
0xE306
Un307
Deviation counter when alarm occurs
0~0xFFFFFFFF
pulse
0xE307
Un308
Main circuit bus voltage when alarm occurs
0~0xFFFF
V
0xE308
Un309
The effective value of current feeDBack
when the alarm occurs
0~0xFFFF
%
0xE309
Un30A
Cumulative load rate when alarm occurs
0~0xFFFF
%
0xE30A
Un30B
Regeneration load rate when alarm occurs
0~0xFFFF
%
0xE30B
Un30C
DB resistance consumes power when the
alarm occurs.
0~0xFFFF
%
0xE30C
Un30D
Maximum cumulative load rate when alarm
occurs
0~0xFFFF
%
0xE30D
Un30E
Moment of inertia ratio when alarm occurs
0~0xFFFF
%
0xE30E
Un30F
Abnormal number of serial encoders
communication when alarm occurs
0~0xFFFF
-
0xE30F
Un310
Internal signal monitoring when alarm
occurs
0~0xFFFFFFFF
-
0xE310
Un313
Monitoring of internal input signal when
alarm occurs
0~0xFFFFFFFF
-
0xE313
Un317
Internal output signal monitoring when
alarm occurs
0~0xFFFFFFFF
-
0xE317
Un320
Fault code history 1
0~0xFFFF
-
0xE320
Un321
Fault code history 2
0~0xFFFF
-
0xE321
Un322
Fault code history 3
0~0xFFFF
-
0xE322
Un323
Fault code history 4
0~0xFFFF
-
0xE323