2
reliably grounded and the earth resistance is less than 10 ohms.
The static electricity of the body will seriously damage the internal sensitive devices. Before conducting related
operations, please comply with the measures and methods stipulated in the electrostatic prevention measure (ESD),
otherwise it may damage the servo system.
Since the output voltage of the servo system is a pulse waveform, if the output side is equipped with a capacitor
for improving the power factor or a varistor for lightning protection, it is necessary to dismantle or refit the input side of
the servo system.
No switching devices such as circuit breakers and contactors should be added to the output side of the servo
system. If the switch device must be connected to the output side, the output current of the servo system must be
guaranteed to be zero when controlling the switch.
No matter where the fault occurs in the control equipment, it is possible to stop production and major accidents.
Therefore, please select the necessary external protective measures or stanDBy devices.
This product can only be used in accordance with the purpose specified by the manufacturer, and shall not be
used in special fields such as emergency, rescue, shipping, medical, aviation, nuclear facilities, etc. without permission.
The maintenance of this product can only be carried out by our company or the professional licensed by the
company. Unauthorized modification and use of non company accessories may result in product failure. Any defective
device must be replaced in time.