35
0x01:
Positioning completed 0x101: Positioning completed signal negation
0x02:
Consistent speed 0x102: Consistent speed signal negation
0x03:
Rotation detection signal 0x103:
Rotation detection signal negation
0x04:
Torque is limiting 0x104: Torque is limiting signal negation
0x05: Speed is limiting 0x105: Speed is limiting signal negation
0x06:
Brake interlock 0x106: Brake interlock signal negation
0x07:Alarm 0x107:Alarm signal negation
0x08:Positioning approach signal 0x108: Positioning approach signal negation
0x09:
Command pulse input integral magnification switching signal
0x109: Command pulse input integral magnification switching signal negation
Pn622
Function selection switch
0x00~0x11
0
-
0x0622
RST
0x1 #: Digital output alarm output (ALM) signal high effective
0x0 #: Digital output alarm output (ALM) signal low effective
0x # 1: No warning is detected
0x # 0: Warning is detected
3.8
Pn7 Extension Related Parameters
Function
code
Parameters
Range
Default
Unit
Address
Effective
way
Pn730
No
-
motor test function
selection
0x00~0x01
0
-
0x0730
RST
0-Invalid 1-Valid
Pn731
No-motor test function
encoder resolution selection
0~3
1
-
0x0731
RST
When the motorless test mode is selected, the resolution of the motor encoder settings
:
0-13bits
1-17bits 2-20bits 3-23bits
Pn732
No-motor test function
encoder type selection
0x00~0x01
0
-
0x0732
RST
Set the encoder type without motor test function
:
0-incremental encoder
1-absolute encoder
Pn792
Absolute encoder operation
0~2
0
-
0x0792
RST
0-
No action 1-
Write motor parameters to encoder EEPROM
2-
Clear the number of encoder turns