AC80T Tower Crane Purpose VFD Manual
19
Switch terminal parameter set
No.
Function description
Range of setting and
definition
Factory
default
Pr
op
ert
y
Com
munic
ation
add.
F2.00
Multifunction input
terminal 1(X1)
0: No function
1: FWD
2: REV
3:Three lines operation
control
4: FWD inching running
5: REV inching running
6:Free stop
7:Emergency stop
8:Fault reset
9: External fault input
15: Multistage speed
terminal 1
16: Multistage speed
terminal 2
17: Multistage speed
terminal 3
18: Multistage speed
terminal 4
46: Brake failure detection
1
●
F2.01
Multifunction input
terminal 2(X2)
2
●
F2.02
Multifunction input
terminal 3(X3)
15
●
F2.03
Multifunction input
terminal 4(X4)
16
●
F2.04
Multifunction input
terminal 5(X5)
17
●
F2.05
Multifunction input
terminal 6(X6)
18
●
F2.06
Multifunction input
terminal 7(X7)
8
●
F2.07
Multifunction input
terminal 8(X8)
46
●
F2.09
X1
~
X4 input terminal
filter time
0.000
~
60.000s 0.030s
●
F2.11
X5
~
X8 input terminal
filter time
0.000
~
60.000s 0.010s
●
F2.29
Output terminal 1
(
Y1
)
0: No output
3:Fault trip alarm 1(alarm
while fault self-recover)
9: FDT function output
20:Hoist band-brake logic
control
29: Phase fault output
30: Brake failure
maintenance
3
●
F2.30
Output terminal 2
(
Y2
)
30
●
F2.31
Relay output terminal
(
TA-TB-TC
)
20
●
F2.32
Upward start frequency
0.00
~
50.00Hz 4.00Hz
●
F2.33
Upward start frequency
delay time
0.00
~
10.00s 0.6
●
F2.34
Upward brake-releasing
current value
0.00
~
500.0% 50.0%
●
F2.35
Upward brake-releasing
current value hold time
0.00
~
10.00s 0.10
●
F2.36
Downward start
frequency
0.00
~
50.00Hz 3.50Hz
●
F2.37
Downward start
frequency delay time
0.00
~
10.00s 0.7
●
F2.38
Downward loose-brake
current value
0.00
~
500.0%
50.0%
●
F2.39
Downward loose-brake
current value hold time
0.00
~
10.00s 0.10
●
F2.40
Upward stop-band
brake frequency
0.00
~
50.00Hz 3.50Hz
●