AC80T Tower Crane Purpose VFD Manual
31
0: Off
1: On
LED thousands digit:
Slewing load frequency
reduction function
0: Off
1: On
F9.12
Flexible control
deviation frequency
0.00
~
20.00Hz 2.00
●
F9.13
Flexible control
acceleration time
0
~
650.00s 20.00
●
F9.14
Flexible control
deceleration time
0
~
650.00s 20.00
●
F9.15 Reserved
F9.16
Reserved
F9.17
Reserved
F9.18
Slewing
acceleration/deceleratio
n time 1 determines the
frequency
0.00
~
100.00Hz 7.50
●
F9.19
Slewing
acceleration/deceleratio
n time 2 determines the
frequency
0.00
~
100.00Hz 50.00
●
F9.20
Slewing
acceleration/deceleratio
n time 3 determines the
frequency
0.00
~
100.00Hz 50.00
●
F9.21 Reserved
Slewing eddy current control parameter set
:
No.
Function description
Range of setting and
definition
Factory
default
Prop
erty
Com
muni
catio
n
Add
FB.00 Reserved
FB.01 Reserved
FB.02 Reserved
FB.03
Start-up duty ratio
increases the frequency
range
0.00
~
320.00Hz 1.00Hz
●
FB.04
Eddy current frequency
segment 1
0.00
~
320.00Hz 4.00Hz
●
FB.05
Eddy current frequency
segment 2
0.00
~
320.00Hz 20.00Hz
●