AC80T Tower Crane Purpose VFD Manual
25
F6.08
ASR filter time 2
0.000
~
0.100s 0.010
●
F6.09
ASR switch frequency 2
0.00
~
50.00Hz 10.00Hz
●
F6.10
Vector slip
compensation
coefficient
0
~
250%
120%
●
F6.11
Max. input torque
20.0
~
250.0% 200.0%
●
F6.12
Constant power area
torque compensation
starting frequency
100.0%
~
500.0% 120.0%
●
F6.13
Constant power area
torque compensation
coefficient
0
~
100% 30%
●
F6.14
Constant power area
torque limiting starting
frequency
100.0%
~
500.0% 200.0%
●
F6.15
Constant power area
torque limiting value
50
~
200% 150%
●
Fault and protection parameter set
No.
Function description
Range of setting and
definition
Factory
default
Pr
op
ert
y
Comm
unicat
ion
add.
FA.00
Protection function
selection 1
LED“0”digit:ACC overcurrent
suppression selection
0: Invalid
1: Valid
LED“10”digit:DEC
overcurrent suppression
selection
0: Invalid
1: Valid
LED“100”digit:Current
limiting selection in
operation
0: Invalid
1: Valid
LED “1000”digit:Reserve
0001
●
FA.01
Protection function
selection 2
LED “0”digit: DEC
over-voltage suppression
protection
0: Invalid
1: Rating 1 over-voltage
suppression
2: Rating 2 over-voltage
suppression
LED “10”digit: Over-voltage
suppression protection in
operation
0: Invalid
1: Valid
LED “100”digit: Motor
overload action selection
0000
●