40
13 Supplement
VEGAPULS 42 • Three-wire with IO-Link (2 x transistor or 4 … 20 mA plus 1 x transistor)
1016153-EN-230316
13 Supplement
13.1 Technical data
Note for approved instruments
The technical data in the respective safety instructions which are included in delivery are valid for
approved instruments (e.g. with Ex approval). These data can differ from the data listed herein, for
example regarding the process conditions or the voltage supply.
All approval documents can be downloaded from our homepage.
Materials and weights
Materials, wetted parts
Process fitting
316L
Antenna
PEEK or PTFE
Process seal
FKM, EPDM
Materials, non-wetted parts
Electronics housing
316L und PBT/PC
Illuminated ring
PC
M12 x 1 plug connector
Ʋ
Contact support
PBT/PC
Ʋ
Contacts
CuZn, nickel layer and 0.8 µm gold-plated
Weight
approx. 0.5 kg (1.12 lbs)
Torques
Thread G¾, ¾ NPT
75 Nm (55.32 lbf ft)
Thread G1, 1 NPT
100 Nm (73.76 lbf ft)
Thread G1 with O-ring
20 Nm (14.76 lbf ft)
Thread G1 with conus
100 Nm (73.76 lbf ft)
Input variable
Measured variable
The measured variable is the distance between the
antenna edge of the sensor and the medium surface.
The antenna edge is also the reference plane for the
measurement.
Max. measuring range
15 m (49.21 ft)
Recommended measuring range
up to 10 m (32.81 ft)
blocking distance
0 mm (0 in)
Switch-on phase
Run-up time for U
B
< 5 s
Starting current active current output
≤ 3.6 mA
IO-Link communication readiness
3 s