Timed:
User defines the duration of the test; after the test is started, the test will run for the configured duration and
stop automatically.
Auto:
User configures the start and end time of the test, selects the type of test to run, and a profile if one has
been previously stored.
The test set must be powered on to carry out and automatic test.
TestType
(Auto Test only)
:
BERT, Throughput, or RFC 2544.
Measurement Settings -Auto Test - BERT & Throughput
Measurement Settings - Auto Test - RFC 2544
Measurement Settings - Manual
Measurement Settings - Timed
Event Log:
Circular or Blocked. Up to 1000 event logs can be stored.
Circular:
Only the latest events will be stored if there are over 1000 event logs. The oldest event will be deleted so
that the new event can be added.
Blocked:
Only the maximum number of events will be stored; any event that occurs after the 1000th event will not
be stored. Event logs consist of a log of the start of test, end of test, errors, alarms, frame loss, etc. The log will
have a timestamp, type of event, and count (number of errors occurring in that instant).
Tx Start:
Coupled or Separate. Configure how the measurements are started when in BERT and Multiple Streams test
modes
Coupled:
Transmitter and receiver are turned on at the same time, and the Tx and Rx measurements start at the
_e-manual_D07-00-051P_RevD00
Summary of Contents for VePal TX130M+
Page 1: ...TX130M _e manual_D07 00 051P_RevD00...
Page 19: ...Go back to top Go back to ToC TX130M _e manual_D07 00 051P_RevD00...
Page 69: ...Go back to top Go back to ToC TX130M _e manual_D07 00 051P_RevD00...
Page 105: ...Go back to top Go back to ToC TX130M _e manual_D07 00 051P_RevD00...
Page 171: ...Go back to top Go back to ToC TX130M _e manual_D07 00 051P_RevD00...