Mag-FLEX Installation And Handling Procedure
Mag-FLEX Probe-To-Surge Protector Wiring Connections
22
2. Make the connections to the four black and white wires in the surge protector using wire nuts as shown in
Figure 5. Depending on the installation, cut off the TLS console or Transmitter cable’s bare shield wire at the
cable jacket.
Figure 5. Splice Connections
3. Center the splices in the clear plastic sleeve. Assemble the surge protector closure, making sure the sleeve is
fully inserted into each of the vinyl end caps. Rotate the sleeve cover until both slot openings line up. Arrange
the closure so the slot openings are facing up and the surge protector is as level as possible.
4. Remove bag of “Sealing compound” from foil package. Grasp the ends, one in each hand, then pull sharply to
remove plastic clip [Figure 6].
WARNING!
Sealing compound contains isocyanate. Vapor and liquid may cause
sensitization. May be irritating to the eyes.
Avoid skin and eye contact. Avoid repeated and prolonged breathing of vapor.
Use only in well ventilated areas. Wear chemically resistant gloves.
Inhalation - provide fresh air. In case of eye contact flush eyes with plenty of
water for 10 minutes and get medical attention. If ingested do not induce
vomiting. Get medical attention. Wash with soap and water in case of skin
contact.
Cable from Transmitter
Connect Probe white to
Surge Protector white
Connect Probe black to
Surge Protector black
Connect Transmitter black
to Surge Protector black
Connect Transmitter white
to Surge Protector white
Enclosure
Bare drain wire
(cut back to
cable jacket)
Cable from probe
Cable from TLS
Connect Probe white to
Surge Protector white
Connect Probe black to
Surge Protector black
Connect TLS white to
Surge Protector white
Connect TLS black to
Surge Protector black
Enclosure
Bare drain wire
(cut back to
cable jacket)
Cable from probe
4mm
2
mimum
Green/Yellow
ground wire
4mm
2
mimum
Green/Yellow
ground wire
Dual Channel - Wired Installations
Single Channel - Wireless Installations