Mag-FLEX Installation And Handling Procedure
Mag-FLEX Probe-To-Surge Protector Wiring Connections
20
Mag-FLEX Probe-To-Surge Protector Wiring Connections
BA-350A SURGE PROTECTOR - WIRED INSTALLATIONS ONLY
1.
Connecting the probe leader cable
- Connect the leader cable supplied with the probe to the M12
connector located on the top of the probe canister. Attach the connector of the supplied Leader Cable to the
M12 connector on the probe head. First tighten the union nut of the M12 connector by hand and then tighten
the nut a further 180° using an open-ended spanner. The tightening torque should be in the range of
100~150 N/cm.
2.
Fitting the screw-in gland assembly
- Connect the other end of the probe leader cable to the surge pro
-
tector as shown below.
3.
Grounding the probe to the tank
A 4 mm² earth cable must be
connected between the probe
canister earth connector and
tank ground.
Black wire (-)
White wire (+)
NOTICE
4mm2
earth
cable