68
UM001
5.2.10
Communication Protocol Control
Communication Protocol Control
Register ID : 30
Access :
Read /
Write
Comment : Contains parameters that controls the communication protocol used by the sensor.
Size (Bytes): 7
Example Response: $VNRRG,30,0,0,0,0,1,0,1*6C
Offset Name
Format
Unit
Description
0
SerialCount
uint8
-
Provides the ability to append a counter or time to the end
of the serial asynchronous messages.
1
SerialStatus
uint8
-
Provides the ability to append the status to the end of the
serial asynchronous messages.
2
SPICount
uint8
-
Provides the ability to append a counter to the end of the
SPI packets.
3
SPIStatus
uint8
-
Provides the ability to append the status to the end of the
SPI packets.
4
SerialChecksum
uint8
-
Choose the type of checksum used for serial
communications.
5
SPIChecksum
uint8
-
Choose the type of checksum used for the SPI
communications.
6
ErrorMode
uint8
-
Choose the action taken when errors are generated.