Menu (exit by menue point 20 or 21)
4. Menu structure
Display
Here alternatively,
the nominal- or
actual value
is displayed
Menu entry after "Up" and "Down" are pressed simultaneously for 5 seconds
00 = Display Software version
01 = Ramp CW
02 = Running down ramp CW
03 = Running up ramp CCW
04 = Clockwise rotation deceleration ramp
05 = Boost
06 = Set Point
00 = Selection button with set point saving
01 = Analog Input selection
02 = Fixed frequency Selection (adjustable in menu point 10 and 11)
03 = Selection button without set point saving
07 = Display representation
00 = Nominal value selection
01 = Actual value selection
08 = Maximum output frequency
09 = Corner frequency
10 = Level of the fixed frequency for CW
11 = Level of the fixed frequency of counter clockwise rotation
12 = Factory setting (see section 6.12)
13 = Output relay function to assign
00 = Collective fault message
01 = Nominal value equal actual value
02 = Actual value equal frequency (Adjustable at menu 14)
03 = Over temperature internal
04 = Zero field frequency (motor turns)
05 = Motor over temperature (PTC)
06 = Error IGBT – Mod
07 = Short circuit motor
08 = Motor over current
09 = DC link overvoltage
10 = Set over current
11 = Frequency inverter ready for operation
14 = Final value frequency (in conjunction with relay function 02)
15 = Over Current limit (motor current)
16 = Adjustment for analog set point
17 = ON/OFF – Button activate/deactivate
18 = Minimal Output frequency
19 = Rotation of the periphery
20 = Exit menu with password loc
21 = Exit the menu without a password lock