Series 65
INSTALLATION
980029EB
Edition 2019-10-11
43/103
4.6
Configuration through CPA
4.6.1
Logic Interface configuration
Interface configuration must be adapted according to application needs.
Default configuration:
OPEN input
CLOSE input
OPEN output
CLOSE output
not inverted
not inverted
open
close
•
Functionality of digital inputs CLOSE VALVE and OPEN VALVE must be selected.
These may be configured as ‘not inverted‘ or ‘inverted‘. Default is ‘not inverted‘.
•
LEARN range configuration for remote operation must be selected.
This may either be ‘full range’ or pressure limit according of analog SETPOINT input. Default is ‘full
range‘.
Local operation:
(‘Control Performance Analyzer’)
Remote operation:
•
With CPA, do configuration in menu
‘Interface / Setup’.
It’s not possible to do ‘Interface
configuration‘ via remote operation.
4.6.1
Homing Start Option
Homing start option defines when the valve performs the homing procedure.
Parameter
Description
Start Condition
Homing start option defines when the valve performs the homing
procedure.
Standard
Do homing after restart if valve is not in
sealed state
Open Command
Do homing on an open command
Move Command
Do homing on any move command
At Startup
Do homing after restart
Homing Command
Do homing on homing command
Move
Command/Standard
Settings from move commands, without
homing in close position by close command
End Control Mode
This control mode is set after a successful homing.
End Position
In case the “End Control Mode” is set to “Position”, this parameter
defines which position is set after successful homing.
Parameter location:
CPA
Valve->Homing