Series 65
ERROR! REFERENCE SOURCE NOT FOUND.
980029EB
Edition 2019-10-11
73/103
‘Ho’ indicates power up
homing is running
H
o
5.6.2
Operation
Description / Mode
Digit 1
Digit 2
Digit 3
Digit 4
Start up (init)
I
n
-
-
Start up (init) leak tight
I
n
-
C
Valve closed (leak tight
)
C
-
-
C
Valve open
O
PRESSURE CONTROL mode
P
0…100
= valve position ( 0 = minimal conductance
100 = max. open)
POSITION CONTROL mode
(e.g. A..0 = min. conductance)
A
Closed / open interlock
(Valve closed / open
by digital input)
I
HOLD (position frozen)
activated
H
LEARN running
L
Safety mode established.
Refer to «Safety mode» for
details.
S
Power failure
F
5.6.3
Error
Description
Digit 1
Digit 2
Digit 3
Digit 4
Error number (xyz)
E
x
y
z
alternately (if error code exist)
Error code
-
u
v
w
For Error number / code. Refer to «Trouble shooting» for details
5.6.4
Safety mode
By means of an external switch (see connection diagrams «Electrical connection») the motor power
supply can be interrupted. In this case the valve enters the ‘safety mode’. This motor interlock prevents
the valve from moving (e.g. maintenance work). Data reading from the control unit remains possible.
When motor interlock is active during power up the valve directly enters the ‘safety mode’ and is not able
to do homing. Display shows ‘S.XXX’ (XXX = value position of valve or C..C for close). In this case
homing cycle will be done when motor interlock is deactivated. Then Display shows ‘Ho’ (Homing) for a
moment followed by ‘A. 0’