Series 65
TROUBLE SHOOTING
980029EB
Edition 2019-10-11
77/103
•
Achsen vertauscht
•
Encoder nicht angeschlossen
1 5 Motion controller: Target position can’t be
reached
•
1)
•
Current settings
1 6 Motion
controller:
Position
minimal
conductance cannot be reached
•
1)
•
Check Plate and Seal ring
•
Check Parameter “Isolation Position Enter
[r]”
1 7 Motion controller: Position to push back
the Differential Plate cannot be reached
•
1)
•
Check Different Plate
•
Check Parameter “Differential Plate Push
Back Position [r]”
1 8 Motion
controller:
Minimal
isolation
position cannot be reached
•
1)
•
Check Plate and Seal ring
•
Check Parameter “Isolation Position [r]”
2 0 Break slippery detected
Replace actuator
3 0 SFV: Motion controller failure in master-
slave communication
Contact vat support
4 0 Compressed air error
Check compressed air
4 2 Power supply, low voltage detected
Check if power supply is ok and is able to deliver
needed power
9 6 SFV: Position deviation axis1 to axis2 at
homing procedure
•
O-Ring sticking
•
1)
9 7 SFV: Position deviation axis1 to axis2 at
operating
1)
9 8 Position error during closing procedure
1)
9 9 Position error at operating
1)
2 0 0 Valve configuration error, not possible to
operate the valve with these configuration
Contact VAT support
7 7 7 Do not operating mode active
1) Mechanical movement problem:
•
Check for differential pressure
•
Remove foreign object in movement area
•
Eliminate tight movement
•
Repair mechanical failure
If you need any further information, please contact one of our service centers. You will find the
addresses on our website: www.vatvalve.com.