08 MOUNTING VENTILATION UNIT/ CONDENSATE
DRAIN
The ventilation unit must be mounted on a wall of sufficient strength. Wall
plugs and screws are not supplied. Use the appropriate fixing materials
depending on the wall structure.
The condensate from the ventilation unit must be discharged in a
proper manner. For this purpose, the ventilation unit must be
connected to the indoor sewage system in a frost-free and airtight
manner.
A siphon is part of this drainage system and must be provided on site
separately. We advise to glue the connection to the ventilation unit or
to connect it airtight by using a seal. The connection to the ventilation
unit is Ø32mm. If the condensate drain is connected to the siphon with
a hose, it is important that the end of the hose is at least
60 mm below the water level. For a fixed connection, we
recommend an additional filling possibility near the siphon.
CONDENSARY FOOD
MOUNTING
VENTILATION
UNIT
min. 1 cm
min. 1 cm
75 cm
61 cm