12MOUNTING SWITCHES
CONNECTION TO A WIRED 3 POSITION SWITCH OR
A 3GANG SWITCH MODULE
To connect a wired 3-position switch, the
ventilation unit must be opened in a correct manner in order to reach the PCB.
This method can be found in the chapter
of the electric pre-heating element. The correct cable must then be led to the
PCB via the cut-out with grommet provided for this purpose in the ventilation
unit.
Finally, connect the cable to terminal X9 "Connection 3 position switch"
according to the following diagram.
3 position switch or
3-fold switching module
Intended grommets in
the ventilation unit
L1 and L3 closed = high (position 3)
L1 and L2 closed = medium (position
2) L1 open = low (position 1)
L1 is connected to terminal C
L2 is
connected to terminal 1 L3 is
connected to terminal 2
Circuit board T350
/T500
Sample circuit
3 position switch NIKO (type
170-45900 + xxx-659336)
X13
X14
brow
n
power cord
230V
˜ 50Hz
yellow/green
X27
blue
C1
2
L1
X17
L2
L3
X9
{