![Vasco T350 Installation Manual Download Page 26](http://html2.mh-extra.com/html/vasco/t350/t350_installation-manual_3593014026.webp)
24PRODUCT SHEET
VENTILATION
SYSTEM D
Type designation
T350
T350
+ 1
sensor
T350
+ 2
sensors
T500
T500
+ 1
sensor
T500
+ 2
sensors
Specific energy consumption (SEC)
-37,85
-40,34
-43,18
-35,56
-38,64
-42,14
[kWh/(m².a)].
Residential ventilation unit (RVE) Non-
residential ventilation unit (NRVE)
RVE
RVE
RVE
RVE
RVE
RVE
RVE/NRVE
One-way ventilation unit (EVE) Two-
way ventilation unit (TVE)
TVE
TVE
TVE
TVE
TVE
TVE
EVE/TVE
Type of drive
Variable
Variable
Variable
Variable
Variable
Variable
Variable/Different speed
Type of heat recovery system Recuperative Recuperative Recuperative Recuperative Recuperative Recuperative
Recuperative/Regenerative
Thermal efficiency heat recovery
88%
88%
88%
87%
87%
87%
%
Maximum flow rate
350
350
350
500
500
500
m³/h]
Electric input power
165
165
165
333
333
333
[W]
Sound power level
48
48
48
51
51
51
dB(A)]
Reference flow rate
0,068
0,068
0,068
0,097
0,097
0,097
m³/s]
Reference differential pressure
50
50
50
50
50
50
Pa]
Specific input power (SPI)
0,223
0,223
0,223
0,285
0,285
0,285
W/(m³/h)]
Control factor
1
0,85
0,65
1
0,85
0,65
1 / 0,95 / 0,85 / 0,65
Maximum percentages of internal leakage
0,65
0,65
0,65
0,45
0,45
0,45
[%]
Maximum percentages of external leakage
0,74
0,74
0,74
0,52
0,52
0,52
[%]
Location and description of the visual
warning signal for the regulated
changing the filters
LED on the supplied RF switch that lights up orange twice (after actuation) when the filters
need to be replaced. The periodical replacement of the air filters is important for the
optimal functioning of the ventilation unit.
Not replacing the air filter has a negative impact on the unit's efficiency and energy
efficiency.
Instructions for installing
controlled suction grilles
in facade for natural air supply
N/A
Internet address for disassembly instructions
Annual electricity consumption (AEC)
324
247
163
402
303
196
kWhelek/a]
Annual Saved Heating (AHS)
"moderate climate"
4528
4584
4658
4493
4554
4635
kWhpe/a]
Annual Saved Heating (AHS)
"warm climate"
2047
2073
2106
2032
2059
2096
kWhpe/a]
Annual Saved Heating (AHS)
"cold climate"
8857
8967
9113
8789
8909
9068
kWhpe/a]