The following two figures show the recommended terminations for screened cables:
Figure 14: Recommended terminations
The connection between the power cable screen and the motor terminal box must be made using either of the two methods
shown in the following figures (on the left with an EMC gland seal and, on the right, with the screen connected to the terminal box
using a clamp):
Figure 15: Recommended connections in the terminal box
The earth protection conductor must be connected to the terminal indicated for said function.
DANGER
A poor earth connection involves a severe risk of electrocution through accidental contact with the motor surface.
T
– Conductor material terminal box S – Cable screen
P
– Earth cable
Gs
– Conductor seals G – EMC gland seal F – Continuous Faraday box