OPERATION AND MAINTENANCE MANUAL
MAC QM MOTORS
PAGE: 43
CODE: CTT42 EDITION: 01 RELEASE: JULY 2016
Subject to technical changes without prior notice
5.2.4
Connections for the fan, thermal sensors and accessories
In the case that the MAC QM motor has been supplied with fan (optional), the fan motor cables must be connected in accordance
with the specified voltage or that given on the fan motor nameplate.
To connect the thermal sensors, use terminals of 1.5 mm
2
on the tip and connect them to the corresponding nylon strip.
5.2.5
Final checks
Before closing the terminal box, check that:
-
The electric connections in the terminal box are fastened tight.
-
There are no protruding wire ends.
-
The power cable screens are correctly connected.
-
The interior of the terminal box is clean and free from leftover cables.
-
All the seals and blanking surfaces are intact.
-
The connection cables are positioned in such a way that they leave a certain amount of room for movement and that
none of the cables are tight or connected in a ‘forced’ way.
-
The connections between the terminals and the cables are correct.
-
The inputs that are not used are fully closed.
After closing the terminal box cover:
-
Make sure that the closing elements are fastened tight.
Summary of Contents for MAC QM
Page 1: ...OPERATION AND MAINTENANCE MANUAL MAC QM MOTORS...
Page 56: ...P CTT 42 ED 01...