5.3
Start-up
5.3.1
Preliminary checks
Before starting the motor, check the following:
-
The motor is correctly aligned, fastened and coupled.
-
All the necessary measures are in place to prevent direct contact with moving or live parts.
-
Service conditions correspond to the information provided on the motor specifications plate.
-
The earth and equipotential connections have been made correctly.
-
The electrical connections are tightly bolted.
-
All the power cables and their respective shields are correctly connected.
-
The other cables are also correctly connected.
-
The frequency converter configuration guarantees that the maximum rotation speed shown on the motor nameplate will
not be exceeded.
-
The machine cooling system operates correctly (rotation direction, rpm, etc.). Also check that the air inlet and outlet are
unblocked.
-
The motor is connected to operate in the right rotation direction.
-
There is a correct reading of the motor safety devices (thermal sensors).
-
The frequency converter is correctly configured: Check the drive configuration data with the motor nameplate and the
technical datasheet.