88
Subject to modification! Updated 12/2017
The initialisation process can be tracked at the LED ring of
the On/Off button.
LED ring
colour
LED action
Operating state
Green
Flashes every
second
Duration approx.
90 s
System check
Green
Steady light
Ready
Red
Steady light
Probable error:
The battery modules have
not yet been configured.
Continue with commissioning!
LED ring
colour
Possible cause
Remedy
White
On/Off button
not pressed
Press On/Off button
Hood not positioned
correctly
Open hood and then position
it as instructed
Fuse not switched
on
Switch on fuse
No
AC grid connection
Check AC grid connection
and establish, if necessary
Switch defective
Check switch and replace, if
necessary