background image

Van der Ende Groep. · Aartsdijkweg 23, 2676 LE, Maasdijk · Telefoon 0174 515050 

IBAN NL71 RABO 0340341610 · KvK Den Haag 27230471 · Btw-nummer NL8000.78.378.B01 · [email protected] · www.vanderendegroep.nl

 

 

 

 

 
 
 

Pagina 8 van 16 

 

1.7

 

Guarantee conditions 

This product is guaranteed for a period of 6 months from the proven date of commissioning, with a 

maximum date of 2 years after the date of production. The proven date of commissioning means the 
date on which the machine was installed.  

If a claim is made on the guarantee, the parts in question must be submitted to the manufacturer for 
evaluation.  
 

The warranty will cease to be valid if any of the following conditions apply: 

 

Improper use or installation 

 

Repeatedly ignoring the advice of the supplier and/or manufacturer 

 

Repair, maintenance or use by unauthorized persons 

 

Use of unsuitable connections with regard to power supply or cables 

 

Use of the machine in an unsuitable environment 

 

Intentional damage or adaptations to the machine 

 

The guarantee conditions are conform to the METAALUNIE CONDITIONS (the Dutch organization for 
small and medium-sized enterprises in the metal industry) published in January 2014. 

1.8

 

CE mark 

The CE mark relates to compliance with the Machinery, Low Voltage, EMC and PED Directives. The 
Enmix Light is an unfinished machine and consequently does not meet all the conditions and essential 

safety requirements at the time of delivery. A list of the conditions and safety requirements that the 
Enmix Light does not meet at the time of delivery may be obtained from the manufacturer.  
The CE mark can be found on the sticker affixed to the motor. 

 
According to the Low Voltage Directive, the Enmix Light is classified as a Class I device. 

1.9

 

Residual risks 

It is practically and economically impossible to cover all risks for the full 100%. Furthermore, one of 
the risks of the machine may be closely connected to its functionality. The so-called residual risks are 

shown in the table below. It is important that the user is aware of the risks involved when using this 
machine. All safety regulations should be followed in order to minimize the risks as much as possible. 

 

Risk page No.  Residual risk description 

Risk factor  Category 

1. 

If the mixer is longer than the support legs, which 

may or may not be present, the Enmix cannot be 
placed in a stable position. This is only applicable 
prior to the installation of the Enmix. 

Table 3: List of residual risks 

Summary of Contents for Enmix Light

Page 1: ...Assembly Manual Enmix Light Agitator mixer Version 1 9 Date February 2022...

Page 2: ...is not connected to the appropriate facility for this installation and consequently it is classified as an unfinished machine This assembly manual contains only those instructions pertinent to the saf...

Page 3: ...tic diagram of the machine 5 1 2 Operation 6 1 3 Use 7 1 4 Users 7 1 5 Media 7 1 6 Operating environment 7 1 7 Guarantee conditions 8 1 8 CE mark 8 1 9 Residual risks 8 2 Description 9 2 1 General 9 2...

Page 4: ...e is stainless steel 304 It s also possible to request the mounting frame as stainless steel 316 This all must be specifically requested The purpose of the machine is to keep liquids in motion in orde...

Page 5: ...Below are the main components of the Enmix Light represented by a number and corresponding name Figure 1 Overview of components Enmix Light No Description 1 Electric motor 2 Capacitor 12 5 F Only at...

Page 6: ...on The Enmix Light is supplied without controls The Enmix Light 230 Vac version is supplied with locking thermal protection and with approximately two meters of cable The Enmix Light must be connected...

Page 7: ...ix Light in general The Enmix Light is not intended to be used without being placed on a liquid reservoir The Enmix is not intended to be used for the purpose of processing foodstuffs 1 4 Users Intend...

Page 8: ...the metal industry published in January 2014 1 8 CE mark The CE mark relates to compliance with the Machinery Low Voltage EMC and PED Directives The Enmix Light is an unfinished machine and consequent...

Page 9: ...mprises a motor and an extended shaft to which a mixing disc has been attached The shaft can be customised to fit every fertilizer bin or other container of liquid substances shorter or shallower than...

Page 10: ...ith the materials of the Enmix Light components that come in contact with them Further information on the application areas can be found under paragraphs 1 5 1 6 and 1 7 Work on the machine or install...

Page 11: ...btained from your supplier Make sure the fluid reservoir which the Enmix light is mounted to is placed on a stable surface Make sure that the Enmix Light is firmly attached to the fertilizer bin or co...

Page 12: ...ft 6 if necessary and ensure that the mixing disc 7 is at least 100 mm above the bottom of the fluid reservoir o The shaft 6 can be shortened using a hacksaw or cutting disc o File away any burrs Inse...

Page 13: ...se practical aids such as a stepladder or a footstool Mount the Enmix Light onto the bin or container Make sure the mixer is fitted with a safety guard and poses no danger to people o Use a cover or g...

Page 14: ...work on the Enmix Pull the plug out of the socket 6 1 Regular checks Frequency monthly Check that the mounting plate is still firmly attached to the reservoir Check that the motor and reduction gearb...

Page 15: ...y Directive 2006 42 EC We declare under our sole responsibility that the machine to which this declaration relates complies with all the provisions of the following Directives and where applicable com...

Page 16: ...de Groep Aartsdijkweg 23 2676 LE Maasdijk Telefoon 0174 515050 IBAN NL71 RABO 0340341610 KvK Den Haag 27230471 Btw nummer NL8000 78 378 B01 info vanderendegroep nl www vanderendegroep nl Pagina 16 van...

Reviews: