Operation/using for the first time
Use the Enmix Light to dissolve chemical agents in water. Do not dissolve long fibres (longer than
5mm) or viscous agents (viscosity > 1000 MPas) with the Enmix.
•
Always make sure that the agents and liquids used are suitable for use in the Enmix Light. The
supplier or manufacturer should be able to send you a list, free of charge, containing a complete
overview of the agents that may or may not be used.
The Enmix Light may be used for acids to a minimum level of pH4.
6
Maintenance
The Enmix Light is practically maintenance free. It is recommended to check the installation each
month and to report any defects to the supplier or the manufacturer.
Always disconnect the power supply before performing any maintenance work on the Enmix. Pull the
plug out of the socket.
6.1
Regular checks
Frequency: monthly
•
Check that the mounting plate is still firmly attached to the reservoir.
•
Check that the motor and reduction gearbox are still firmly attached to the mounting plate.
•
Check that the mixer disc can rotate freely.
•
Make sure that the mixing disc is mounted at least 100 mm from the bottom of the reservoir.
•
Make sure that the mixing disc is free of fixed elements and that all ports are open.
•
Check that the mixer shaft is straight
7
Malfunctions
Below is a table of possible malfunctions and their cause. Always make sure that the power supply is
disconnected prior to carrying out any repair work to the Enmix Light.
Problem
Cause
Solution
The mixer no longer turns
No power
Check power supply
Thermal protection is switched
off
Remove any large parts in the bin
or container and press the
thermal protection reset button
Condenser is broken
Replace condenser
Thermal protection switches off
repeatedly
Too much dirt on the mixing
disc (clogged)
Remove large parts and press the
thermal protection reset button
Shaft is bent
Contact your supplier
Table 4 Malfunctions and solutions